Btus (th)/hour/sq. foot/°F to Calories (it)/second/cm²/°C Converter (Btu (th)/(h·ft²·°F) to cal/(s·cm²·°C))
Btu (th)/(h·ft²·°F) × 0.00013553231 = cal/(s·cm²·°C)
Calculation: 1 Btu (th)/(h·ft²·°F) × 0.00013553231 = 0.00013553231 cal/(s·cm²·°C)
Common BTU (th)/hour/sq. foot/°F to Calorie (IT)/second/cm²/°C Calculations
Quick-lookup reference table showing calculated equivalents for standard increments between BTU (th)/hour/sq. foot/°F (Btu (th)/(h·ft²·°F)) and Calorie (IT)/second/cm²/°C (cal/(s·cm²·°C)).
| Conversion & Equivalent Value | Scientific Notation |
|---|---|
| 0.001 Btu (th)/(h·ft²·°F) 1.355323 × 10⁻⁷ cal/(s·cm²·°C) | 1.355 × 10⁻⁷ |
| 0.01 Btu (th)/(h·ft²·°F) 1.355323 × 10⁻⁶ cal/(s·cm²·°C) | 1.355 × 10⁻⁶ |
| 0.1 Btu (th)/(h·ft²·°F) 1.355323 × 10⁻⁵ cal/(s·cm²·°C) | 1.355 × 10⁻⁵ |
| 0.5 Btu (th)/(h·ft²·°F) 6.776615 × 10⁻⁵ cal/(s·cm²·°C) | 6.777 × 10⁻⁵ |
| 1 Btu (th)/(h·ft²·°F) 0.000135532 cal/(s·cm²·°C) | 1.355 × 10⁻⁴ |
| 2 Btu (th)/(h·ft²·°F) 0.000271065 cal/(s·cm²·°C) | 2.711 × 10⁻⁴ |
| 5 Btu (th)/(h·ft²·°F) 0.000677662 cal/(s·cm²·°C) | 6.777 × 10⁻⁴ |
| 10 Btu (th)/(h·ft²·°F) 0.00135532 cal/(s·cm²·°C) | 1.355 × 10⁻³ |
| 20 Btu (th)/(h·ft²·°F) 0.00271065 cal/(s·cm²·°C) | 2.711 × 10⁻³ |
| 25 Btu (th)/(h·ft²·°F) 0.00338831 cal/(s·cm²·°C) | 3.388 × 10⁻³ |
| 50 Btu (th)/(h·ft²·°F) 0.00677662 cal/(s·cm²·°C) | 6.777 × 10⁻³ |
| 100 Btu (th)/(h·ft²·°F) 0.0135532 cal/(s·cm²·°C) | 1.355 × 10⁻² |
| 250 Btu (th)/(h·ft²·°F) 0.0338831 cal/(s·cm²·°C) | 3.388 × 10⁻² |
| 500 Btu (th)/(h·ft²·°F) 0.0677662 cal/(s·cm²·°C) | 6.777 × 10⁻² |
| 1000 Btu (th)/(h·ft²·°F) 0.135532 cal/(s·cm²·°C) | 1.355 × 10⁻¹ |
| Reciprocal & Equivalent Value | Scientific Notation |
|---|---|
| 1 cal/(s·cm²·°C) 7378.314555 Btu (th)/(h·ft²·°F) | 7.378 × 10³ |
| 5 cal/(s·cm²·°C) 36891.572776 Btu (th)/(h·ft²·°F) | 3.689 × 10⁴ |
| 10 cal/(s·cm²·°C) 73783.145553 Btu (th)/(h·ft²·°F) | 7.378 × 10⁴ |
| 50 cal/(s·cm²·°C) 368915.727763 Btu (th)/(h·ft²·°F) | 3.689 × 10⁵ |
| 100 cal/(s·cm²·°C) 737831.455526 Btu (th)/(h·ft²·°F) | 7.378 × 10⁵ |
Real-World Context & Everyday Benchmarks
Tap to load into converterTo help contextualize these units in everyday life, science, and engineering, here are verified real-world reference points for BTU (th)/hour/sq. foot/°F (Btu (th)/(h·ft²·°F)) and Calorie (IT)/second/cm²/°C (cal/(s·cm²·°C)):
BTU (th)/hour/sq. foot/°F References:
- Stationary ambient air natural free convection on vertical wall 0.88114 Btu (th)/(h·ft²·°F)
- Forced air breeze blowing across automotive cooling radiator 8.8114 Btu (th)/(h·ft²·°F)
- Liquid water forced circulation inside heat exchanger pipe 528.68 Btu (th)/(h·ft²·°F)
- Nucleate boiling heat transfer in pressurized steam boiler tube 2643.42 Btu (th)/(h·ft²·°F)
Calorie (IT)/second/cm²/°C References:
- Stationary ambient air natural free convection on vertical wall 0.000119 cal/(s·cm²·°C)
- Forced air breeze blowing across automotive cooling radiator 0.001194 cal/(s·cm²·°C)
- Liquid water forced circulation inside heat exchanger pipe 0.071654 cal/(s·cm²·°C)
- Nucleate boiling heat transfer in pressurized steam boiler tube 0.358269 cal/(s·cm²·°C)
How to Convert BTU (th)/hour/sq. foot/°F to Calorie (IT)/second/cm²/°C
Converting BTU (th)/hour/sq. foot/°F (Btu (th)/(h·ft²·°F)) to Calorie (IT)/second/cm²/°C (cal/(s·cm²·°C)) is a core calculation in Heat Transfer Coefficient, which quantifies the proportionality constant between the heat flux and the thermodynamic driving temperature difference. This calculation navigates the boundary between the International Metric System (SI) and British Imperial / US Customary engineering standards. In contemporary metrology, Imperial units are defined in terms of exact SI standards via international agreements—notably NIST SP 811 and the 1959 International Yard and Pound Agreement. Exactly 1 BTU (th)/hour/sq. foot/°F equals 0.000135532 Calorie (IT)/second/cm²/°C, while 1 cal/(s·cm²·°C) equals 7378.314555 Btu (th)/(h·ft²·°F).
Mathematical Conversion Derivation via Coherent SI Base Unit
Under the International System of Quantities (ISQ), dimensional conversion between non-SI units is rigorously resolved by bridging through the coherent SI base unit (watt per square meter kelvin (W/(m²·K))) without arbitrary rounding:
1 Btu (th)/(h·ft²·°F) = 5.674467 watt per square meter kelvin (W/(m²·K))1 cal/(s·cm²·°C) = 41868 watt per square meter kelvin (W/(m²·K))V(cal/(s·cm²·°C)) = V(Btu (th)/(h·ft²·°F)) × ( 5.674467 / 41868 ) = V(Btu (th)/(h·ft²·°F)) × 0.000135532Value in Calorie (IT)/second/cm²/°C = Value in BTU (th)/hour/sq. foot/°F × 0.00013553231Direct computational formula applied for standard conversion.Converting 36 Btu (th)/(h·ft²·°F) yields an exact output of 0.00487916 cal/(s·cm²·°C) in Calorie (IT)/second/cm²/°C. Under higher industrial throughput, 240 Btu (th)/(h·ft²·°F) translates to 0.0325278 cal/(s·cm²·°C).
Inverse check: 1 cal/(s·cm²·°C) = 7378.314555 Btu (th)/(h·ft²·°F).Understanding BTU (th)/hour/sq. foot/°F and Calorie (IT)/second/cm²/°C
BTU (th)/hour/sq. foot/°F
Btu (th)/(h·ft²·°F)A BTU (th)/hour/sq. foot/°F (Btu (th)/(h·ft²·°F)) is an imperial and US customary unit for heat transfer coefficient.
Applications & Practical Context
In practical heat transfer coefficient terms, a stationary ambient air natural free convection on vertical wall equals 0.88114 Btu (th)/(h·ft²·°F), a forced air breeze blowing across automotive cooling radiator equals 8.8114 Btu (th)/(h·ft²·°F), a liquid water forced circulation inside heat exchanger pipe equals 528.68 Btu (th)/(h·ft²·°F).
A physical magnitude of 1 Btu (th)/(h·ft²·°F) corresponds to 5.674467 W/(m²·K) in standard SI measurement.
1 Btu (th)/(h·ft²·°F) = 5.674467 W/(m²·K)Calorie (IT)/second/cm²/°C
cal/(s·cm²·°C)A Calorie (IT)/second/cm²/°C (cal/(s·cm²·°C)) is a recognized unit for heat transfer coefficient.
Applications & Practical Context
In practical heat transfer coefficient terms, a stationary ambient air natural free convection on vertical wall equals 0.000119 cal/(s·cm²·°C), a forced air breeze blowing across automotive cooling radiator equals 0.001194 cal/(s·cm²·°C), a liquid water forced circulation inside heat exchanger pipe equals 0.071654 cal/(s·cm²·°C).
A physical magnitude of 1 cal/(s·cm²·°C) corresponds to 41868 W/(m²·K) in standard SI measurement.
1 cal/(s·cm²·°C) = 41868 W/(m²·K)Domain Metrology & Engineering Applications
Newton's Law of Cooling (q = h · ΔT)
Rigorously quantified in laboratory and field settings using surface heat flux transducer plates coupled with surface RTD arrays, and wind tunnel boundary layer calorimeters.
Applied across industrial heat exchanger rating, nuclear reactor cooling loop simulation, electronics forced-air cooling, and architectural U-value certification under international metrology standard ISO 80000-5:2019, ASME PTC.
Formulas, conversion coefficients, and base definitions on this page strictly adhere to the ISO 80000-5:2019, ASME PTC and the BIPM SI Brochure (9th Edition). Governed by Newton's Law of Cooling (q = h · ΔT) under ISO 80000 dimensional vector [M T⁻³ Θ⁻¹].
Heat Transfer Coefficient to Convective Flux Bridge (W/m² • kW/m² • BTU/(h·ft²) • cal/(s·cm²))
Calculate Newton’s law of cooling convective heat flux q" = h × ΔT across convective film temperature drops, bridging heat transfer coefficient [M T⁻³ Θ⁻¹] with heat flux [M T⁻³].
q" = h × ΔT
[W/(m²·K)] × [K] → [W/m²]
-
1. Normalize Input to SI Base Unit (W/(m²·K)):
h = 1 Btu (th)/(h·ft²·°F) × 5.67446667 = 5.67446667 W/(m²·K) -
2. Apply Engineering Parameter (ΔT):
Selected condition: Forced Air Duct Cooling (ΔT = 25 K) at ΔT = 25 K -
3. Execute Governing Physical Law in SI Units:
q" = h × ΔT = (5.67446667 W/(m²·K)) × (25 K) = 141.861667 W/m² -
4. Convert to Standard Engineering Units:
• W/m²: 141.861667 × 1 = 141.8617 W/m² (Watts per Square Meter) • kW/m²: 141.861667 × 0.001 = 0.1419 kW/m² (Kilowatts per Square Meter) • BTU/(h·ft²): 141.861667 × 0.317 = 44.9699 BTU/(h·ft²) (BTU per Hour Sq. Foot) • cal/(s·cm²): 141.861667 × 2.3885 × 10⁻⁵ = 0.00338831 cal/(s·cm²) (Calories per Second Sq. Cm) • Ly/min: 141.861667 × 0.001433 = 0.2033 Ly/min (Langley per Minute) • MW/m²: 141.861667 × 1 × 10⁻⁶ = 0.00014186 MW/m² (Megawatts per Square Meter)
| Engineering Substance / Operating Standard | Parameter Value (K) | Reference State / Condition | Typical Industrial & Engineering Application |
|---|---|---|---|
| Natural Air Convection (ΔT = 15 K) | 15 |
ΔT = 15 K (15°C) | Still room air room heating surface delta |
| Forced Air Duct Cooling (ΔT = 25 K) | 25 |
ΔT = 25 K (25°C) | Forced fan ventilation heatsink airflow |
| Forced Liquid Water Cooling (ΔT = 30 K) | 30 |
ΔT = 30 K | Pumped liquid cold plate or engine jacket |
| Nucleate Boiling Heat Transfer (ΔT = 50 K) | 50 |
ΔT = 50 K | Boiler evaporator tube wall boundary |
Frequently Asked Questions
Related BTU (th)/hour/sq. foot/°F and Calorie (IT)/second/cm²/°C Conversions
Convert BTU (th)/hour/sq. foot/°F to Other Units
Convert Other Units to Calorie (IT)/second/cm²/°C
Physically Coupled Thermodynamics & Heat Converters
Explore interconnected physical dimension converters within the Thermodynamics & Heat cluster (ISO 80000-5:2019).