Chus/hour/sq. foot/°C to Calories (it)/second/cm²/°C Converter (CHU/(h·ft²·°C) to cal/(s·cm²·°C))
CHU/(h·ft²·°C) × 0.00013562082 = cal/(s·cm²·°C)
Calculation: 1 CHU/(h·ft²·°C) × 0.00013562082 = 0.00013562082 cal/(s·cm²·°C)
Common CHU/hour/sq. foot/°C to Calorie (IT)/second/cm²/°C Calculations
Quick-lookup reference table showing calculated equivalents for standard increments between CHU/hour/sq. foot/°C (CHU/(h·ft²·°C)) and Calorie (IT)/second/cm²/°C (cal/(s·cm²·°C)).
| Conversion & Equivalent Value | Scientific Notation |
|---|---|
| 0.001 CHU/(h·ft²·°C) 1.356208 × 10⁻⁷ cal/(s·cm²·°C) | 1.356 × 10⁻⁷ |
| 0.01 CHU/(h·ft²·°C) 1.356208 × 10⁻⁶ cal/(s·cm²·°C) | 1.356 × 10⁻⁶ |
| 0.1 CHU/(h·ft²·°C) 1.356208 × 10⁻⁵ cal/(s·cm²·°C) | 1.356 × 10⁻⁵ |
| 0.5 CHU/(h·ft²·°C) 6.781041 × 10⁻⁵ cal/(s·cm²·°C) | 6.781 × 10⁻⁵ |
| 1 CHU/(h·ft²·°C) 0.000135621 cal/(s·cm²·°C) | 1.356 × 10⁻⁴ |
| 2 CHU/(h·ft²·°C) 0.000271242 cal/(s·cm²·°C) | 2.712 × 10⁻⁴ |
| 5 CHU/(h·ft²·°C) 0.000678104 cal/(s·cm²·°C) | 6.781 × 10⁻⁴ |
| 10 CHU/(h·ft²·°C) 0.00135621 cal/(s·cm²·°C) | 1.356 × 10⁻³ |
| 20 CHU/(h·ft²·°C) 0.00271242 cal/(s·cm²·°C) | 2.712 × 10⁻³ |
| 25 CHU/(h·ft²·°C) 0.00339052 cal/(s·cm²·°C) | 3.391 × 10⁻³ |
| 50 CHU/(h·ft²·°C) 0.00678104 cal/(s·cm²·°C) | 6.781 × 10⁻³ |
| 100 CHU/(h·ft²·°C) 0.0135621 cal/(s·cm²·°C) | 1.356 × 10⁻² |
| 250 CHU/(h·ft²·°C) 0.0339052 cal/(s·cm²·°C) | 3.391 × 10⁻² |
| 500 CHU/(h·ft²·°C) 0.0678104 cal/(s·cm²·°C) | 6.781 × 10⁻² |
| 1000 CHU/(h·ft²·°C) 0.135621 cal/(s·cm²·°C) | 1.356 × 10⁻¹ |
| Reciprocal & Equivalent Value | Scientific Notation |
|---|---|
| 1 cal/(s·cm²·°C) 7373.499084 CHU/(h·ft²·°C) | 7.373 × 10³ |
| 5 cal/(s·cm²·°C) 36867.49542 CHU/(h·ft²·°C) | 3.687 × 10⁴ |
| 10 cal/(s·cm²·°C) 73734.99084 CHU/(h·ft²·°C) | 7.373 × 10⁴ |
| 50 cal/(s·cm²·°C) 368674.9542 CHU/(h·ft²·°C) | 3.687 × 10⁵ |
| 100 cal/(s·cm²·°C) 737349.9084 CHU/(h·ft²·°C) | 7.373 × 10⁵ |
Real-World Context & Everyday Benchmarks
Tap to load into converterTo help contextualize these units in everyday life, science, and engineering, here are verified real-world reference points for CHU/hour/sq. foot/°C (CHU/(h·ft²·°C)) and Calorie (IT)/second/cm²/°C (cal/(s·cm²·°C)):
CHU/hour/sq. foot/°C References:
- Stationary ambient air natural free convection on vertical wall 0.880565 CHU/(h·ft²·°C)
- Forced air breeze blowing across automotive cooling radiator 8.8057 CHU/(h·ft²·°C)
- Liquid water forced circulation inside heat exchanger pipe 528.34 CHU/(h·ft²·°C)
- Nucleate boiling heat transfer in pressurized steam boiler tube 2641.7 CHU/(h·ft²·°C)
Calorie (IT)/second/cm²/°C References:
- Stationary ambient air natural free convection on vertical wall 0.000119 cal/(s·cm²·°C)
- Forced air breeze blowing across automotive cooling radiator 0.001194 cal/(s·cm²·°C)
- Liquid water forced circulation inside heat exchanger pipe 0.071654 cal/(s·cm²·°C)
- Nucleate boiling heat transfer in pressurized steam boiler tube 0.358269 cal/(s·cm²·°C)
How to Convert CHU/hour/sq. foot/°C to Calorie (IT)/second/cm²/°C
Converting CHU/hour/sq. foot/°C (CHU/(h·ft²·°C)) to Calorie (IT)/second/cm²/°C (cal/(s·cm²·°C)) is a core calculation in Heat Transfer Coefficient, which quantifies the proportionality constant between the heat flux and the thermodynamic driving temperature difference. This calculation navigates the boundary between the International Metric System (SI) and British Imperial / US Customary engineering standards. In contemporary metrology, Imperial units are defined in terms of exact SI standards via international agreements—notably NIST SP 811 and the 1959 International Yard and Pound Agreement. Exactly 1 CHU/hour/sq. foot/°C equals 0.000135621 Calorie (IT)/second/cm²/°C, while 1 cal/(s·cm²·°C) equals 7373.499084 CHU/(h·ft²·°C).
Mathematical Conversion Derivation via Coherent SI Base Unit
Under the International System of Quantities (ISQ), dimensional conversion between non-SI units is rigorously resolved by bridging through the coherent SI base unit (watt per square meter kelvin (W/(m²·K))) without arbitrary rounding:
1 CHU/(h·ft²·°C) = 5.678173 watt per square meter kelvin (W/(m²·K))1 cal/(s·cm²·°C) = 41868 watt per square meter kelvin (W/(m²·K))V(cal/(s·cm²·°C)) = V(CHU/(h·ft²·°C)) × ( 5.678173 / 41868 ) = V(CHU/(h·ft²·°C)) × 0.000135621Value in Calorie (IT)/second/cm²/°C = Value in CHU/hour/sq. foot/°C × 0.00013562082Direct computational formula applied for standard conversion.To convert 24 CHU/hour/sq. foot/°C (CHU/(h·ft²·°C)) to Calorie (IT)/second/cm²/°C (cal/(s·cm²·°C)): multiply 24 by 0.000135621 to get 0.0032549 cal/(s·cm²·°C). At an industrial engineering scale, 10000 CHU/(h·ft²·°C) converts to 1.356208 cal/(s·cm²·°C).
Inverse check: 1 cal/(s·cm²·°C) = 7373.499084 CHU/(h·ft²·°C).Understanding CHU/hour/sq. foot/°C and Calorie (IT)/second/cm²/°C
CHU/hour/sq. foot/°C
CHU/(h·ft²·°C)A CHU/hour/sq. foot/°C (CHU/(h·ft²·°C)) is an imperial and US customary unit for heat transfer coefficient.
Applications & Practical Context
In practical heat transfer coefficient terms, a stationary ambient air natural free convection on vertical wall equals 0.880565 CHU/(h·ft²·°C), a forced air breeze blowing across automotive cooling radiator equals 8.8057 CHU/(h·ft²·°C), a liquid water forced circulation inside heat exchanger pipe equals 528.34 CHU/(h·ft²·°C).
A physical magnitude of 1 CHU/(h·ft²·°C) corresponds to 5.678173 W/(m²·K) in standard SI measurement.
1 CHU/(h·ft²·°C) = 5.678173 W/(m²·K)Calorie (IT)/second/cm²/°C
cal/(s·cm²·°C)A Calorie (IT)/second/cm²/°C (cal/(s·cm²·°C)) is a recognized unit for heat transfer coefficient.
Applications & Practical Context
In practical heat transfer coefficient terms, a stationary ambient air natural free convection on vertical wall equals 0.000119 cal/(s·cm²·°C), a forced air breeze blowing across automotive cooling radiator equals 0.001194 cal/(s·cm²·°C), a liquid water forced circulation inside heat exchanger pipe equals 0.071654 cal/(s·cm²·°C).
A physical magnitude of 1 cal/(s·cm²·°C) corresponds to 41868 W/(m²·K) in standard SI measurement.
1 cal/(s·cm²·°C) = 41868 W/(m²·K)Domain Metrology & Engineering Applications
Newton's Law of Cooling (q = h · ΔT)
Rigorously quantified in laboratory and field settings using surface heat flux transducer plates coupled with surface RTD arrays, and wind tunnel boundary layer calorimeters.
Applied across industrial heat exchanger rating, nuclear reactor cooling loop simulation, electronics forced-air cooling, and architectural U-value certification under international metrology standard ISO 80000-5:2019, ASME PTC.
Formulas, conversion coefficients, and base definitions on this page strictly adhere to the ISO 80000-5:2019, ASME PTC and the BIPM SI Brochure (9th Edition). Governed by Newton's Law of Cooling (q = h · ΔT) under ISO 80000 dimensional vector [M T⁻³ Θ⁻¹].
Heat Transfer Coefficient to Convective Flux Bridge (W/m² • kW/m² • BTU/(h·ft²) • cal/(s·cm²))
Calculate Newton’s law of cooling convective heat flux q" = h × ΔT across convective film temperature drops, bridging heat transfer coefficient [M T⁻³ Θ⁻¹] with heat flux [M T⁻³].
q" = h × ΔT
[W/(m²·K)] × [K] → [W/m²]
-
1. Normalize Input to SI Base Unit (W/(m²·K)):
h = 1 CHU/(h·ft²·°C) × 5.67817254 = 5.67817254 W/(m²·K) -
2. Apply Engineering Parameter (ΔT):
Selected condition: Forced Air Duct Cooling (ΔT = 25 K) at ΔT = 25 K -
3. Execute Governing Physical Law in SI Units:
q" = h × ΔT = (5.67817254 W/(m²·K)) × (25 K) = 141.954313 W/m² -
4. Convert to Standard Engineering Units:
• W/m²: 141.954313 × 1 = 141.9543 W/m² (Watts per Square Meter) • kW/m²: 141.954313 × 0.001 = 0.142 kW/m² (Kilowatts per Square Meter) • BTU/(h·ft²): 141.954313 × 0.317 = 44.9993 BTU/(h·ft²) (BTU per Hour Sq. Foot) • cal/(s·cm²): 141.954313 × 2.3885 × 10⁻⁵ = 0.00339052 cal/(s·cm²) (Calories per Second Sq. Cm) • Ly/min: 141.954313 × 0.001433 = 0.2035 Ly/min (Langley per Minute) • MW/m²: 141.954313 × 1 × 10⁻⁶ = 0.00014195 MW/m² (Megawatts per Square Meter)
| Engineering Substance / Operating Standard | Parameter Value (K) | Reference State / Condition | Typical Industrial & Engineering Application |
|---|---|---|---|
| Natural Air Convection (ΔT = 15 K) | 15 |
ΔT = 15 K (15°C) | Still room air room heating surface delta |
| Forced Air Duct Cooling (ΔT = 25 K) | 25 |
ΔT = 25 K (25°C) | Forced fan ventilation heatsink airflow |
| Forced Liquid Water Cooling (ΔT = 30 K) | 30 |
ΔT = 30 K | Pumped liquid cold plate or engine jacket |
| Nucleate Boiling Heat Transfer (ΔT = 50 K) | 50 |
ΔT = 50 K | Boiler evaporator tube wall boundary |
Frequently Asked Questions
Related CHU/hour/sq. foot/°C and Calorie (IT)/second/cm²/°C Conversions
Convert Other Units to Calorie (IT)/second/cm²/°C
Physically Coupled Thermodynamics & Heat Converters
Explore interconnected physical dimension converters within the Thermodynamics & Heat cluster (ISO 80000-5:2019).