Calories (it)/second/square centimeter/°C to Chus/hour/square foot/°C Converter (cal/(s·cm²·°C) to CHU/(h·ft²·°C))
cal/(s·cm²·°C) × 7373.37028881 = CHU/(h·ft²·°C)
Calculation: 1 cal/(s·cm²·°C) × 7373.37028881 = 7373.37028881 CHU/(h·ft²·°C)
Common Calorie (IT)/second/square centimeter/°C to CHU/hour/square foot/°C Calculations
Quick-lookup reference table showing calculated equivalents for standard increments between Calorie (IT)/second/square centimeter/°C (cal/(s·cm²·°C)) and CHU/hour/square foot/°C (CHU/(h·ft²·°C)).
| Conversion & Equivalent Value | Scientific Notation |
|---|---|
| 0.001 cal/(s·cm²·°C) 7.37337 CHU/(h·ft²·°C) | 7.373 × 10⁰ |
| 0.01 cal/(s·cm²·°C) 73.733703 CHU/(h·ft²·°C) | 7.373 × 10¹ |
| 0.1 cal/(s·cm²·°C) 737.337029 CHU/(h·ft²·°C) | 7.373 × 10² |
| 0.5 cal/(s·cm²·°C) 3686.685144 CHU/(h·ft²·°C) | 3.687 × 10³ |
| 1 cal/(s·cm²·°C) 7373.370289 CHU/(h·ft²·°C) | 7.373 × 10³ |
| 2 cal/(s·cm²·°C) 14746.740578 CHU/(h·ft²·°C) | 1.475 × 10⁴ |
| 5 cal/(s·cm²·°C) 36866.851444 CHU/(h·ft²·°C) | 3.687 × 10⁴ |
| 10 cal/(s·cm²·°C) 73733.702888 CHU/(h·ft²·°C) | 7.373 × 10⁴ |
| 20 cal/(s·cm²·°C) 147467.405776 CHU/(h·ft²·°C) | 1.475 × 10⁵ |
| 25 cal/(s·cm²·°C) 184334.25722 CHU/(h·ft²·°C) | 1.843 × 10⁵ |
| 50 cal/(s·cm²·°C) 368668.51444 CHU/(h·ft²·°C) | 3.687 × 10⁵ |
| 100 cal/(s·cm²·°C) 737337.028881 CHU/(h·ft²·°C) | 7.373 × 10⁵ |
| 250 cal/(s·cm²·°C) 1843342.572201 CHU/(h·ft²·°C) | 1.843 × 10⁶ |
| 500 cal/(s·cm²·°C) 3686685.144403 CHU/(h·ft²·°C) | 3.687 × 10⁶ |
| 1000 cal/(s·cm²·°C) 7373370.288805 CHU/(h·ft²·°C) | 7.373 × 10⁶ |
| Reciprocal & Equivalent Value | Scientific Notation |
|---|---|
| 1 CHU/(h·ft²·°C) 0.000135623 cal/(s·cm²·°C) | 1.356 × 10⁻⁴ |
| 5 CHU/(h·ft²·°C) 0.000678116 cal/(s·cm²·°C) | 6.781 × 10⁻⁴ |
| 10 CHU/(h·ft²·°C) 0.00135623 cal/(s·cm²·°C) | 1.356 × 10⁻³ |
| 50 CHU/(h·ft²·°C) 0.00678116 cal/(s·cm²·°C) | 6.781 × 10⁻³ |
| 100 CHU/(h·ft²·°C) 0.0135623 cal/(s·cm²·°C) | 1.356 × 10⁻² |
Real-World Context & Everyday Benchmarks
Tap to load into converterTo help contextualize these units in everyday life, science, and engineering, here are verified real-world reference points for Calorie (IT)/second/square centimeter/°C (cal/(s·cm²·°C)) and CHU/hour/square foot/°C (CHU/(h·ft²·°C)):
Calorie (IT)/second/square centimeter/°C References:
- High-velocity liquid sodium fast reactor heat exchanger core 0.5 cal/(s·cm²·°C)
CHU/hour/square foot/°C References:
- British thermal engineering shell-and-tube heat exchanger 150 CHU/(h·ft²·°C)
How to Convert Calorie (IT)/second/square centimeter/°C to CHU/hour/square foot/°C
Converting Calorie (IT)/second/square centimeter/°C (cal/(s·cm²·°C)) to CHU/hour/square foot/°C (CHU/(h·ft²·°C)) is a core calculation in Heat Transfer Coefficient, which quantifies the proportionality constant between the heat flux and the thermodynamic driving temperature difference. This calculation navigates the boundary between the International Metric System (SI) and British Imperial / US Customary engineering standards. In contemporary metrology, Imperial units are defined in terms of exact SI standards via international agreements—notably NIST SP 811 and the 1959 International Yard and Pound Agreement. Exactly 1 Calorie (IT)/second/square centimeter/°C equals 7373.370289 CHU/hour/square foot/°C, while 1 CHU/(h·ft²·°C) equals 0.000135623 cal/(s·cm²·°C).
Mathematical Conversion Derivation via Coherent SI Base Unit
Under the International System of Quantities (ISQ), dimensional conversion between non-SI units is rigorously resolved by bridging through the coherent SI base unit (watt per square meter kelvin (W/(m²·K))) without arbitrary rounding:
1 cal/(s·cm²·°C) = 41867.98188 watt per square meter kelvin (W/(m²·K))1 CHU/(h·ft²·°C) = 5.678269 watt per square meter kelvin (W/(m²·K))V(CHU/(h·ft²·°C)) = V(cal/(s·cm²·°C)) × ( 41867.98188 / 5.678269 ) = V(cal/(s·cm²·°C)) × 7373.370289Value in CHU/hour/square foot/°C = Value in Calorie (IT)/second/square centimeter/°C × 7373.37028881Direct computational formula applied for standard conversion.Converting 250 cal/(s·cm²·°C) yields an exact output of 1843342.572201 CHU/(h·ft²·°C) in CHU/hour/square foot/°C. Under higher industrial throughput, 480 cal/(s·cm²·°C) translates to 3539217.738627 CHU/(h·ft²·°C).
Inverse check: 1 CHU/(h·ft²·°C) = 0.000135623 cal/(s·cm²·°C).Understanding Calorie (IT)/second/square centimeter/°C and CHU/hour/square foot/°C
Calorie (IT)/second/square centimeter/°C
cal/(s·cm²·°C)A Calorie (IT)/second/square centimeter/°C (cal/(s·cm²·°C)) is a recognized unit for heat transfer coefficient.
Applications & Practical Context
In practical heat transfer coefficient terms, a high-velocity liquid sodium fast reactor heat exchanger core equals 0.5 cal/(s·cm²·°C).
A physical magnitude of 1 cal/(s·cm²·°C) corresponds to 41867.98188 W/(m²·K) in standard SI measurement.
1 cal/(s·cm²·°C) = 41867.98188 W/(m²·K)CHU/hour/square foot/°C
CHU/(h·ft²·°C)A CHU/hour/square foot/°C (CHU/(h·ft²·°C)) is an imperial and US customary unit for heat transfer coefficient.
Applications & Practical Context
In practical heat transfer coefficient terms, a British thermal engineering shell-and-tube heat exchanger equals 150 CHU/(h·ft²·°C).
A physical magnitude of 1 CHU/(h·ft²·°C) corresponds to 5.678269 W/(m²·K) in standard SI measurement.
1 CHU/(h·ft²·°C) = 5.678269 W/(m²·K)Domain Metrology & Engineering Applications
Newton's Law of Cooling (q = h · ΔT)
Rigorously quantified in laboratory and field settings using surface heat flux transducer plates coupled with surface RTD arrays, and wind tunnel boundary layer calorimeters.
Applied across industrial heat exchanger rating, nuclear reactor cooling loop simulation, electronics forced-air cooling, and architectural U-value certification under international metrology standard ISO 80000-5:2019, ASME PTC.
Formulas, conversion coefficients, and base definitions on this page strictly adhere to the ISO 80000-5:2019, ASME PTC and the BIPM SI Brochure (9th Edition). Governed by Newton's Law of Cooling (q = h · ΔT) under ISO 80000 dimensional vector [M T⁻³ Θ⁻¹].
Heat Transfer Coefficient to Convective Flux Bridge (W/m² • kW/m² • BTU/(h·ft²) • cal/(s·cm²))
Calculate Newton’s law of cooling convective heat flux q" = h × ΔT across convective film temperature drops, bridging heat transfer coefficient [M T⁻³ Θ⁻¹] with heat flux [M T⁻³].
q" = h × ΔT
[W/(m²·K)] × [K] → [W/m²]
-
1. Normalize Input to SI Base Unit (W/(m²·K)):
h = 1 cal/(s·cm²·°C) × 41867.98187954 = 41867.98187954 W/(m²·K) -
2. Apply Engineering Parameter (ΔT):
Selected condition: Forced Air Duct Cooling (ΔT = 25 K) at ΔT = 25 K -
3. Execute Governing Physical Law in SI Units:
q" = h × ΔT = (41867.98187954 W/(m²·K)) × (25 K) = 1046699.546988 W/m² -
4. Convert to Standard Engineering Units:
• W/m²: 1046699.546988 × 1 = 1046699.547 W/m² (Watts per Square Meter) • kW/m²: 1046699.546988 × 0.001 = 1046.6995 kW/m² (Kilowatts per Square Meter) • BTU/(h·ft²): 1046699.546988 × 0.317 = 331802.0775 BTU/(h·ft²) (BTU per Hour Sq. Foot) • cal/(s·cm²): 1046699.546988 × 2.3885 × 10⁻⁵ = 24.999989 cal/(s·cm²) (Calories per Second Sq. Cm) • Ly/min: 1046699.546988 × 0.001433 = 1500.2693 Ly/min (Langley per Minute) • MW/m²: 1046699.546988 × 1 × 10⁻⁶ = 1.0467 MW/m² (Megawatts per Square Meter)
| Engineering Substance / Operating Standard | Parameter Value (K) | Reference State / Condition | Typical Industrial & Engineering Application |
|---|---|---|---|
| Natural Air Convection (ΔT = 15 K) | 15 |
ΔT = 15 K (15°C) | Still room air room heating surface delta |
| Forced Air Duct Cooling (ΔT = 25 K) | 25 |
ΔT = 25 K (25°C) | Forced fan ventilation heatsink airflow |
| Forced Liquid Water Cooling (ΔT = 30 K) | 30 |
ΔT = 30 K | Pumped liquid cold plate or engine jacket |
| Nucleate Boiling Heat Transfer (ΔT = 50 K) | 50 |
ΔT = 50 K | Boiler evaporator tube wall boundary |
Frequently Asked Questions
Related Calorie (IT)/second/square centimeter/°C and CHU/hour/square foot/°C Conversions
Convert Calorie (IT)/second/square centimeter/°C to Other Units
Convert Other Units to CHU/hour/square foot/°C
Physically Coupled Thermodynamics & Heat Converters
Explore interconnected physical dimension converters within the Thermodynamics & Heat cluster (ISO 80000-5:2019).