Skip to main content

Btus (th)/second/square foot/°F to Chus/hour/square foot/°C Converter (Btu (th)/(s·ft²·°F) to CHU/(h·ft²·°C))

Rate this converter 0 of 0 ratings
Instant calculation with 0ms overhead
Popular Converters
Live Conversion • ISO 80000-5:2019 Certified
1 Btu (th)/second/square foot/°F = 3597.60581794 CHU/hour/square foot/°C
1 Btu (th)/(s·ft²·°F) = 3597.605818 CHU/(h·ft²·°C) • 1 CHU/(h·ft²·°C) = 0.000277963 Btu (th)/(s·ft²·°F)
Btu (th)/second/square foot/°F to CHU/hour/square foot/°C: One Btu (th)/second/square foot/°F is equal to 3597.60581794 Chus/hour/square foot/°C.
Certified Authority Value
3597.60581794
CHU/(h·ft²·°C)
Exact: 1 CHU/(h·ft²·°C) ≡ 0.000277962637 Btu (th)/(s·ft²·°F)
Btu (th)/(s·ft²·°F)
Btu (th)/(s·ft²·°F)
CHU/(h·ft²·°C)
CHU/(h·ft²·°C) 3597.60581794
Quick Values:
Conversion Formula
To convert Btu (th)/second/square foot/°F to CHU/hour/square foot/°C, multiply by 3597.60581794
Btu (th)/(s·ft²·°F) × 3597.60581794 = CHU/(h·ft²·°C)

Calculation: 1 Btu (th)/(s·ft²·°F) × 3597.60581794 = 3597.60581794 CHU/(h·ft²·°C)

Common Btu (th)/second/square foot/°F to CHU/hour/square foot/°C Calculations

Quick-lookup reference table showing calculated equivalents for standard increments between Btu (th)/second/square foot/°F (Btu (th)/(s·ft²·°F)) and CHU/hour/square foot/°C (CHU/(h·ft²·°C)).

Tap any row to calculate
Btu (th)/second/square foot/°F to CHU/hour/square foot/°C: Primary Direct Table (15 Steps)
Btu (th)/second/square foot/°F to CHU/hour/square foot/°C Conversion Reference Table
Conversion & Equivalent Value Scientific Notation
0.001 Btu (th)/(s·ft²·°F) 3.597606 CHU/(h·ft²·°C) 3.598 × 10⁰
0.01 Btu (th)/(s·ft²·°F) 35.976058 CHU/(h·ft²·°C) 3.598 × 10¹
0.1 Btu (th)/(s·ft²·°F) 359.760582 CHU/(h·ft²·°C) 3.598 × 10²
0.5 Btu (th)/(s·ft²·°F) 1798.802909 CHU/(h·ft²·°C) 1.799 × 10³
1 Btu (th)/(s·ft²·°F) 3597.605818 CHU/(h·ft²·°C) 3.598 × 10³
2 Btu (th)/(s·ft²·°F) 7195.211636 CHU/(h·ft²·°C) 7.195 × 10³
5 Btu (th)/(s·ft²·°F) 17988.02909 CHU/(h·ft²·°C) 1.799 × 10⁴
10 Btu (th)/(s·ft²·°F) 35976.058179 CHU/(h·ft²·°C) 3.598 × 10⁴
20 Btu (th)/(s·ft²·°F) 71952.116359 CHU/(h·ft²·°C) 7.195 × 10⁴
25 Btu (th)/(s·ft²·°F) 89940.145449 CHU/(h·ft²·°C) 8.994 × 10⁴
50 Btu (th)/(s·ft²·°F) 179880.290897 CHU/(h·ft²·°C) 1.799 × 10⁵
100 Btu (th)/(s·ft²·°F) 359760.581794 CHU/(h·ft²·°C) 3.598 × 10⁵
250 Btu (th)/(s·ft²·°F) 899401.454486 CHU/(h·ft²·°C) 8.994 × 10⁵
500 Btu (th)/(s·ft²·°F) 1798802.908972 CHU/(h·ft²·°C) 1.799 × 10⁶
1000 Btu (th)/(s·ft²·°F) 3597605.817944 CHU/(h·ft²·°C) 3.598 × 10⁶
CHU/hour/square foot/°C to Btu (th)/second/square foot/°F: Reciprocal Summary
CHU/hour/square foot/°C to Btu (th)/second/square foot/°F Conversion Reference Table
Reciprocal & Equivalent Value Scientific Notation
1 CHU/(h·ft²·°C) 0.000277963 Btu (th)/(s·ft²·°F) 2.78 × 10⁻⁴
5 CHU/(h·ft²·°C) 0.00138981 Btu (th)/(s·ft²·°F) 1.39 × 10⁻³
10 CHU/(h·ft²·°C) 0.00277963 Btu (th)/(s·ft²·°F) 2.78 × 10⁻³
50 CHU/(h·ft²·°C) 0.0138981 Btu (th)/(s·ft²·°F) 1.39 × 10⁻²
100 CHU/(h·ft²·°C) 0.0277963 Btu (th)/(s·ft²·°F) 2.78 × 10⁻²

Real-World Context & Everyday Benchmarks

Tap to load into converter

To help contextualize these units in everyday life, science, and engineering, here are verified real-world reference points for Btu (th)/second/square foot/°F (Btu (th)/(s·ft²·°F)) and CHU/hour/square foot/°C (CHU/(h·ft²·°C)):

Btu (th)/second/square foot/°F References:

  • High-pressure steam boiler water-wall tube boiling coefficient 0.5 Btu (th)/(s·ft²·°F)

CHU/hour/square foot/°C References:

  • British thermal engineering shell-and-tube heat exchanger 150 CHU/(h·ft²·°C)
ISQ Dimension: [M T⁻³ Θ⁻¹] Coherent SI Unit: watt per square meter kelvin (W/(m²·K)) Thermodynamics & Heat Transfer

How to Convert Btu (th)/second/square foot/°F to CHU/hour/square foot/°C

Converting Btu (th)/second/square foot/°F (Btu (th)/(s·ft²·°F)) to CHU/hour/square foot/°C (CHU/(h·ft²·°C)) is a core calculation in Heat Transfer Coefficient, which quantifies the proportionality constant between the heat flux and the thermodynamic driving temperature difference. This calculation navigates the boundary between the International Metric System (SI) and British Imperial / US Customary engineering standards. In contemporary metrology, Imperial units are defined in terms of exact SI standards via international agreements—notably NIST SP 811 and the 1959 International Yard and Pound Agreement. Exactly 1 Btu (th)/second/square foot/°F equals 3597.605818 CHU/hour/square foot/°C, while 1 CHU/(h·ft²·°C) equals 0.000277963 Btu (th)/(s·ft²·°F).

Direct Factor1 Btu (th)/(s·ft²·°F) = 3597.605818 CHU/(h·ft²·°C)
Inverse Ratio1 CHU/(h·ft²·°C) = 0.000277963 Btu (th)/(s·ft²·°F)
Conversion ScaleMetric SI to British Imperial / US Customary Bridge
First-Principles SI Derivation ProofNIST SP 811 / ISO 80000 Compliance

Mathematical Conversion Derivation via Coherent SI Base Unit

Under the International System of Quantities (ISQ), dimensional conversion between non-SI units is rigorously resolved by bridging through the coherent SI base unit (watt per square meter kelvin (W/(m²·K))) without arbitrary rounding:

Vtarget=Vsource×(ksource→SIktarget→SI)V_{\text{target}} = V_{\text{source}} \times \left( \frac{k_{\text{source} \to \text{SI}}}{k_{\text{target} \to \text{SI}}} \right)
Universal Dimensional Conversion Law (ISO 80000 / NIST SP 811)
1. Source SI Bridge (ksource):1 Btu (th)/(s·ft²·°F) = 20428.174538 watt per square meter kelvin (W/(m²·K))
2. Target SI Bridge (ktarget):1 CHU/(h·ft²·°C) = 5.678269 watt per square meter kelvin (W/(m²·K))
Step-by-step substitution for Btu (th)/second/square foot/°F → CHU/hour/square foot/°C:V(CHU/(h·ft²·°C)) = V(Btu (th)/(s·ft²·°F)) × ( 20428.174538 / 5.678269 ) = V(Btu (th)/(s·ft²·°F)) × 3597.605818
Mathematical FormulaValue in CHU/hour/square foot/°C = Value in Btu (th)/second/square foot/°F × 3597.60581794Direct computational formula applied for standard conversion.
Worked Example

Converting 250 Btu (th)/(s·ft²·°F) yields an exact output of 899401.454486 CHU/(h·ft²·°C) in CHU/hour/square foot/°C. Under higher industrial throughput, 240 Btu (th)/(s·ft²·°F) translates to 863425.396307 CHU/(h·ft²·°C).

Inverse check: 1 CHU/(h·ft²·°C) = 0.000277963 Btu (th)/(s·ft²·°F).

Understanding Btu (th)/second/square foot/°F and CHU/hour/square foot/°C

Btu (th)/second/square foot/°F

Btu (th)/(s·ft²·°F)
Imperial / US

A Btu (th)/second/square foot/°F (Btu (th)/(s·ft²·°F)) is an imperial and US customary unit for heat transfer coefficient.

Applications & Practical Context

In practical heat transfer coefficient terms, a high-pressure steam boiler water-wall tube boiling coefficient equals 0.5 Btu (th)/(s·ft²·°F).

Physical Setup

A physical magnitude of 1 Btu (th)/(s·ft²·°F) corresponds to 20428.174538 W/(m²·K) in standard SI measurement.

Conversion to SI Unit: watt per square meter kelvin (W/(m²·K))
1 Btu (th)/(s·ft²·°F) = 20428.174538 W/(m²·K)

CHU/hour/square foot/°C

CHU/(h·ft²·°C)
Imperial / US

A CHU/hour/square foot/°C (CHU/(h·ft²·°C)) is an imperial and US customary unit for heat transfer coefficient.

Applications & Practical Context

In practical heat transfer coefficient terms, a British thermal engineering shell-and-tube heat exchanger equals 150 CHU/(h·ft²·°C).

Physical Setup

A physical magnitude of 1 CHU/(h·ft²·°C) corresponds to 5.678269 W/(m²·K) in standard SI measurement.

Conversion to SI Unit: watt per square meter kelvin (W/(m²·K))
1 CHU/(h·ft²·°C) = 5.678269 W/(m²·K)

Domain Metrology & Engineering Applications

Governing Law & Equation

Newton's Law of Cooling (q = h · ΔT)

Measurement Instrumentation

Rigorously quantified in laboratory and field settings using surface heat flux transducer plates coupled with surface RTD arrays, and wind tunnel boundary layer calorimeters.

Primary Industry Sectors

Applied across industrial heat exchanger rating, nuclear reactor cooling loop simulation, electronics forced-air cooling, and architectural U-value certification under international metrology standard ISO 80000-5:2019, ASME PTC.

Institutional Metrology & Standard Authority:

Formulas, conversion coefficients, and base definitions on this page strictly adhere to the ISO 80000-5:2019, ASME PTC and the BIPM SI Brochure (9th Edition). Governed by Newton's Law of Cooling (q = h · ΔT) under ISO 80000 dimensional vector [M T⁻³ Θ⁻¹].

Multi-Variable Engineering Bridge Convective Thermodynamics & Cooling

Heat Transfer Coefficient to Convective Flux Bridge (W/m² • kW/m² • BTU/(h·ft²) • cal/(s·cm²))

Calculate Newton’s law of cooling convective heat flux q" = h × ΔT across convective film temperature drops, bridging heat transfer coefficient [M T⁻³ Θ⁻¹] with heat flux [M T⁻³].

q" = h × ΔT
Vector: [W/(m²·K)] × [K] → [W/m²]
Live Calculated Bridge Equivalent:
1 Btu (th)/(s·ft²·°F) at Forced Air Duct Cooling (ΔT = 25 K) = 510704.3635 W/m²
Equals 510.7044 kW/m² • 161892.464 BTU/(h·ft²) • 12.197964 cal/(s·cm²)
SI Heat Flux
510704.3635
W/m²
Watts per Square Meter
Solar / Combustion
510.7044
kW/m²
Kilowatts per Square Meter
US Building Envelope
161892.464
BTU/(h·ft²)
BTU per Hour Sq. Foot
CGS Thermal
12.197964
cal/(s·cm²)
Calories per Second Sq. Cm
Meteorology
732.0096
Ly/min
Langley per Minute
Furnace Flux
0.510704
MW/m²
Megawatts per Square Meter
  1. 1. Normalize Input to SI Base Unit (W/(m²·K)):
    h = 1 Btu (th)/(s·ft²·°F) × 20428.17453832 = 20428.17453832 W/(m²·K)
  2. 2. Apply Engineering Parameter (ΔT):
    Selected condition: Forced Air Duct Cooling (ΔT = 25 K) at ΔT = 25 K
  3. 3. Execute Governing Physical Law in SI Units:
    q" = h × ΔT = (20428.17453832 W/(m²·K)) × (25 K) = 510704.363458 W/m²
  4. 4. Convert to Standard Engineering Units:
    • W/m²: 510704.363458 × 1 = 510704.3635 W/m² (Watts per Square Meter) • kW/m²: 510704.363458 × 0.001 = 510.7044 kW/m² (Kilowatts per Square Meter) • BTU/(h·ft²): 510704.363458 × 0.317 = 161892.464 BTU/(h·ft²) (BTU per Hour Sq. Foot) • cal/(s·cm²): 510704.363458 × 2.3885 × 10⁻⁵ = 12.197964 cal/(s·cm²) (Calories per Second Sq. Cm) • Ly/min: 510704.363458 × 0.001433 = 732.0096 Ly/min (Langley per Minute) • MW/m²: 510704.363458 × 1 × 10⁻⁶ = 0.510704 MW/m² (Megawatts per Square Meter)
Explore Full Heat Flux Density Converter →
Engineering Substance / Operating Standard Parameter Value (K) Reference State / Condition Typical Industrial & Engineering Application
Natural Air Convection (ΔT = 15 K) 15 ΔT = 15 K (15°C) Still room air room heating surface delta
Forced Air Duct Cooling (ΔT = 25 K) 25 ΔT = 25 K (25°C) Forced fan ventilation heatsink airflow
Forced Liquid Water Cooling (ΔT = 30 K) 30 ΔT = 30 K Pumped liquid cold plate or engine jacket
Nucleate Boiling Heat Transfer (ΔT = 50 K) 50 ΔT = 50 K Boiler evaporator tube wall boundary
Embed
Need this Btu (th)/second/square foot/°F to CHU/hour/square foot/°C calculator on your website, lab portal, or research blog?
Free HTML Widget 100% Responsive Zero Cookie Tracking
Notice a calculation discrepancy, rounding error, or glitch?
Help us maintain 100% scientific precision and report any issues directly to engineering.

Frequently Asked Questions

There are exactly 3597.60581794 chus/hour/square foot/°c (CHU/(h·ft²·°C)) in 1 btu (th)/second/square foot/°f (Btu (th)/(s·ft²·°F)). To calculate larger amounts manually, simply multiply your total number of btus (th)/second/square foot/°f by the conversion multiplier of 3597.60581794.

The mathematical formula to convert btus (th)/second/square foot/°f to chus/hour/square foot/°c is: [value] * 3597.60581794 = chus/hour/square foot/°c. Rather than doing the math manually, you can use our high-precision online calculator to process this exact equation instantly without rounding errors.

To perform the reverse calculation from chus/hour/square foot/°c back to btus (th)/second/square foot/°f, you must divide your starting value by 3597.60581794. Our bidirectional tool automatically computes this inverse equation the moment you type into the chu/hour/square foot/°c input field.

1 Btu (th)/second/square foot/°F is larger than 1 CHU/hour/square foot/°C. Specifically, 1 Btu (th)/second/square foot/°F equals exactly 3597.60581794 chus/hour/square foot/°c, making it 3597.6058 times larger (a difference of 3.56 orders of magnitude). Therefore, quantities expressed in chus/hour/square foot/°c require a larger numerical value to represent the same physical amount.

Under standard international measurement guidelines, 1 Btu (th)/second/square foot/°F converts to 3597.60581794 chus/hour/square foot/°c. Precise numerical conversion factors ensure consistency across laboratory, engineering, and field data.