Poise to Pound Force Seconds/sq. inch Converter (P to reyn)
P × 1.45037744 × 10⁻⁵ = reyn
Calculation: 1 P × 1.45037744 × 10⁻⁵ = 1.45037744 × 10⁻⁵ reyn
Common Poise to Pound-force second/sq. inch Calculations
Quick-lookup reference table showing calculated equivalents for standard increments between Poise (P) and Pound-force second/sq. inch (reyn).
| Conversion & Equivalent Value | Scientific Notation |
|---|---|
| 0.001 P 1.450377 × 10⁻⁸ reyn | 1.45 × 10⁻⁸ |
| 0.01 P 1.450377 × 10⁻⁷ reyn | 1.45 × 10⁻⁷ |
| 0.1 P 1.450377 × 10⁻⁶ reyn | 1.45 × 10⁻⁶ |
| 0.5 P 7.251887 × 10⁻⁶ reyn | 7.252 × 10⁻⁶ |
| 1 P 1.450377 × 10⁻⁵ reyn | 1.45 × 10⁻⁵ |
| 2 P 2.900755 × 10⁻⁵ reyn | 2.901 × 10⁻⁵ |
| 5 P 7.251887 × 10⁻⁵ reyn | 7.252 × 10⁻⁵ |
| 10 P 0.000145038 reyn | 1.45 × 10⁻⁴ |
| 20 P 0.000290075 reyn | 2.901 × 10⁻⁴ |
| 25 P 0.000362594 reyn | 3.626 × 10⁻⁴ |
| 50 P 0.000725189 reyn | 7.252 × 10⁻⁴ |
| 100 P 0.00145038 reyn | 1.45 × 10⁻³ |
| 250 P 0.00362594 reyn | 3.626 × 10⁻³ |
| 500 P 0.00725189 reyn | 7.252 × 10⁻³ |
| 1000 P 0.0145038 reyn | 1.45 × 10⁻² |
| Reciprocal & Equivalent Value | Scientific Notation |
|---|---|
| 1 reyn 68947.57 P | 6.895 × 10⁴ |
| 5 reyn 344737.85 P | 3.447 × 10⁵ |
| 10 reyn 689475.7 P | 6.895 × 10⁵ |
| 50 reyn 3447378.5 P | 3.447 × 10⁶ |
| 100 reyn 6894757 P | 6.895 × 10⁶ |
Real-World Context & Everyday Benchmarks
Tap to load into converterTo help contextualize these units in everyday life, science, and engineering, here are verified real-world reference points for Poise (P) and Pound-force second/sq. inch (reyn):
Poise References:
- Pure liquid water dynamic viscosity at room temperature (0.01 P / 1 cP) 0.01 P
- Commercial culinary golden pancake syrup dynamic viscosity 25 P
Pound-force second/sq. inch References:
- Pure drinking water dynamic viscosity at 20 degrees Celsius 0 reyn
- Culinary extra virgin olive oil dynamic viscosity at room temperature 1.2E-5 reyn
- Automotive engine motor oil SAE 30 dynamic viscosity at 20°C 2.9E-5 reyn
- Pure natural clover bee honey dynamic viscosity at room temperature 0.00145 reyn
How to Convert Poise to Pound-force second/sq. inch
Converting Poise (P) to Pound-force second/sq. inch (reyn) is a core calculation in Dynamic Viscosity, which quantifies a fluid's internal tangential resistance to shear deformation and laminar flow. This calculation bridges modern MKSA metric standards with the historical Gaussian centimetre-gram-second (CGS) electrostatic and electromagnetic framework. In CGS systems, electromagnetic units (such as statvolts, abvolts, dynes, ergs, and gauss) are formulated directly from mechanical dimensions, with electrostatic-to-electromagnetic relations tied to the speed of light in vacuum (c ≈ 2.99792458 × 1010 cm/s). Exactly 1 Poise translates to 1.450377 × 10⁻⁵ Pound-force second/sq. inch (1 reyn = 68947.57 P).
Mathematical Conversion Derivation via Coherent SI Base Unit
Under the International System of Quantities (ISQ), dimensional conversion between non-SI units is rigorously resolved by bridging through the coherent SI base unit (pascal second (Pa·s)) without arbitrary rounding:
1 P = 0.1 pascal second (Pa·s)1 reyn = 6894.757 pascal second (Pa·s)V(reyn) = V(P) × ( 0.1 / 6894.757 ) = V(P) × 1.450377 × 10⁻⁵Value in Pound-force second/sq. inch = Value in Poise × 1.45037744 × 10⁻⁵Direct computational formula applied for standard conversion.Evaluating an input of 24 Poise (P) produces 0.000348091 Pound-force second/sq. inch (reyn). In heavy-duty utility and industrial workloads, 1000 P equals 0.0145038 reyn.
Inverse check: 1 reyn = 68947.57 P.Understanding Poise and Pound-force second/sq. inch
Poise
PA Poise (P) is a unit of dynamic viscosity in the centimeter-gram-second (CGS) system.
Applications & Practical Context
In practical viscosity dynamic terms, a pure liquid water dynamic viscosity at room temperature (0.01 P / 1 cP) equals 0.01 P, a commercial culinary golden pancake syrup dynamic viscosity equals 25 P.
A physical magnitude of 1 P corresponds to 0.1 Pa·s in standard SI measurement.
1 P = 0.1 Pa·sPound-force second/sq. inch
reynA Pound-force second/sq. inch (reyn) is an imperial and US customary unit for dynamic viscosity.
Applications & Practical Context
In practical viscosity dynamic terms, a pure drinking water dynamic viscosity at 20 degrees Celsius equals 0 reyn, a culinary extra virgin olive oil dynamic viscosity at room temperature equals 1.2 × 10⁻⁵ reyn, a automotive engine motor oil SAE 30 dynamic viscosity at 20°C equals 2.9 × 10⁻⁵ reyn.
A physical magnitude of 1 reyn corresponds to 6894.757 Pa·s in standard SI measurement.
1 reyn = 6894.757 Pa·sDomain Metrology & Engineering Applications
Newton's Law of Viscosity (τ = μ · du/dy)
Rigorously quantified in laboratory and field settings using rotational cone-and-plate rheometers, falling ball Höppler viscometers, and vibrating wire viscometers.
Applied across lubricating oil tribology (SAE engine grades), polymer extrusion, paint and coating formulation, and pharmaceutical liquid processing under international metrology standard ISO 80000-4:2019, ASTM D445.
Formulas, conversion coefficients, and base definitions on this page strictly adhere to the ISO 80000-4:2019, ASTM D445 and the BIPM SI Brochure (9th Edition). Governed by Newton's Law of Viscosity (τ = μ · du/dy) under ISO 80000 dimensional vector [M L⁻¹ T⁻¹].
Dynamic to Kinematic Viscosity Bridge (m²/s • cSt • Stokes • ft²/s • in²/s • mm²/s)
Calculate fluid kinematic momentum diffusivity ν = μ / ρ across process liquids, bridging dynamic viscosity [M L⁻¹ T⁻¹] and kinematic viscosity [L² T⁻¹] via metrological density (ρ).
ν = μ / ρ
[Pa·s] ÷ [kg/m³] → [m²/s]
-
1. Normalize Input to SI Base Unit (Pa·s):
μ = 1 P × 0.1 = 0.1 Pa·s -
2. Apply Engineering Parameter (ρ):
Selected condition: Engine Lubricating Oil (SAE 30, 20°C) at ρ = 885 kg/m³ -
3. Execute Governing Physical Law in SI Units:
ν = μ / ρ = (0.1 Pa·s) ÷ (885 kg/m³) = 0.00011299 m²/s -
4. Convert to Standard Engineering Units:
• m²/s: 0.00011299 × 1 = 0.00011299 m²/s (Square Meters per Second) • cSt: 0.00011299 × 1000000 = 112.9944 cSt (Centistokes) • St: 0.00011299 × 10000 = 1.1299 St (Stokes) • ft²/s: 0.00011299 × 10.7639 = 0.001216 ft²/s (Square Feet per Second) • in²/s: 0.00011299 × 1550.0031 = 0.18 in²/s (Square Inches per Second) • mm²/s: 0.00011299 × 1000000 = 112.9944 mm²/s (Square Millimeters per Second)
| Engineering Substance / Operating Standard | Parameter Value (kg/m³) | Reference State / Condition | Typical Industrial & Engineering Application |
|---|---|---|---|
| Water (20°C / Standard Ambient) | 998.2 |
998.2 kg/m³ | Hydronic HVAC & cooling water (NIST) |
| Engine Lubricating Oil (SAE 30, 20°C) | 885 |
885.0 kg/m³ | Crankcase lubrication & turbo bearing feeds |
| Hydraulic Oil (ISO VG 46, 20°C) | 870 |
870.0 kg/m³ | Industrial hydraulic systems & servo controls |
| Heavy Fuel Oil (Bunker C / HFO, 50°C) | 920 |
920.0 kg/m³ | Marine diesel engines & power plant burners |
| Pure Glycerol (100% C₃H₈O₃, 20°C) | 1260 |
1,260.0 kg/m³ | High-viscosity metrology reference fluid |
Frequently Asked Questions
Related Poise and Pound-force second/sq. inch Conversions
Convert Other Units to Pound-force second/sq. inch
Physically Coupled Fluid Dynamics & Rheology Converters
Explore interconnected physical dimension converters within the Fluid Dynamics & Rheology cluster (ISO 80000-4:2019 / ISO 12572).