Liter/minute to Liter/second (L/min to L/s) Calculator & Formula
L/min × 0.016666667 = L/s
Calculation: 1 L/min × 0.016666667 = 0.016666667 L/s
Common Liter/minute to Liter/second Calculations
Quick-lookup reference table showing calculated equivalents for standard increments between Liter/minute (L/min) and Liter/second (L/s).
| Reciprocal & Equivalent Value | Scientific Notation |
|---|---|
| 1 L/s is equal to 60 L/min (Liter/minute) | 6 × 10¹ |
| 5 L/s is equal to 300 L/min (Liter/minute) | 3 × 10² |
| 10 L/s is equal to 600 L/min (Liter/minute) | 6 × 10² |
| 50 L/s is equal to 3000 L/min (Liter/minute) | 3 × 10³ |
| 100 L/s is equal to 6000 L/min (Liter/minute) | 6 × 10³ |
Real-World Context & Everyday Benchmarks
Tap to load into converterTo help contextualize these units in everyday life, science, and engineering, here are verified real-world reference points for Liter/minute (L/min) and Liter/second (L/s):
Liter/minute References:
- Standard water-saving residential bathroom showerhead water flow limit 9 L/min
- Standard domestic kitchen sink faucet aerator maximum flow rate 6 L/min
- Resting adult human pulmonary ventilation air inhalation flow rate 6 L/min
Liter/second References:
- Standard residential outdoor garden watering hose discharge rate 0.5 L/s
- Municipal fire engine attack hose line water discharge delivery rate 15 L/s
How to Convert Liter/minute to Liter/second
Converting Liter/minute (L/min) to Liter/second (L/s) is a core calculation in Volumetric Flow Rate, which quantifies the volume of fluid passing through a designated conduit cross-section per unit of time. Because Liter/second is a broader physical scale than Liter/minute, converting from L/min to L/s condenses the numerical figure. It takes 60 Liter/minute to equal a single Liter/second (1 L/min = 0.0166667 L/s). To convert any quantity, multiply by 0.0166667 (or divide by 60).
Mathematical Conversion Derivation via Coherent SI Base Unit
Under the International System of Quantities (ISQ), dimensional conversion between non-SI units is rigorously resolved by bridging through the coherent SI base unit (cubic meter per second (m³/s)) without arbitrary rounding:
1 L/min = 1.666667 × 10⁻⁵ cubic meter per second (m³/s)1 L/s = 0.001 cubic meter per second (m³/s)V(L/s) = V(L/min) × ( 1.666667 × 10⁻⁵ / 0.001 ) = V(L/min) × 0.0166667Value in Liter/second = Value in Liter/minute × 0.016666667Direct computational formula applied for standard conversion.Evaluating an input of 12 Liter/minute (L/min) produces 0.2 Liter/second (L/s). In heavy-duty utility and industrial workloads, 480 L/min equals 8 L/s.
Inverse check: 1 L/s = 60 L/min.Understanding Liter/minute and Liter/second
Liter/minute
L/minA Liter/minute (L/min) is a recognized unit for volumetric flow rate.
Applications & Practical Context
In practical flow terms, a standard water-saving residential bathroom showerhead water flow limit equals 9 L/min, a standard domestic kitchen sink faucet aerator maximum flow rate equals 6 L/min, a resting adult human pulmonary ventilation air inhalation flow rate equals 6 L/min.
A physical magnitude of 1 L/min corresponds to 1.666667 × 10⁻⁵ m³/s in standard SI measurement.
1 L/min = 1.666667 × 10⁻⁵ m³/sLiter/second
L/sA Liter/second (L/s) is a recognized unit for volumetric flow rate.
Applications & Practical Context
In practical flow terms, a standard residential outdoor garden watering hose discharge rate equals 0.5 L/s, a municipal fire engine attack hose line water discharge delivery rate equals 15 L/s.
A physical magnitude of 1 L/s corresponds to 0.001 m³/s in standard SI measurement.
1 L/s = 0.001 m³/sDomain Metrology & Engineering Applications
Hydrodynamic Continuity Equation (Q = A · v̄)
Rigorously quantified in laboratory and field settings using electromagnetic inductive flowmeters, ultrasonic transit-time meters, turbine flowmeters, and differential orifice plates.
Applied across municipal water supply distribution, chemical process loops, oil & gas pipeline custody transfer, and HVAC hydronic balancing under international metrology standard ISO 80000-4:2019, ASME MFC-3M.
Physical Orders of Magnitude & Laboratory Reference Benchmarks
| Physical Phenomenon / Engineering Reference | Reference Value | Converted to Liter/second |
|---|---|---|
| Standard water-saving residential bathroom showerhead water flow limit | 9 L/min | 0.15 L/s |
| Standard domestic kitchen sink faucet aerator maximum flow rate | 6 L/min | 0.1 L/s |
| Resting adult human pulmonary ventilation air inhalation flow rate | 6 L/min | 0.1 L/s |
Formulas, conversion coefficients, and base definitions on this page strictly adhere to the ISO 80000-4:2019, ASME MFC-3M and the BIPM SI Brochure (9th Edition). Governed by Hydrodynamic Continuity Equation (Q = A · v̄) under ISO 80000 dimensional vector [L³ T⁻¹].
Volumetric Flow & Fluid Continuity Bridge (GPM • CFM • m³/h • L/min • L/s • ft³/h)
Directly convert mass flow rate (ṁ) into volumetric flow (Q) across process fluids using the thermodynamic continuity equation ṁ = ρ × Q, bridging mass flow [M T⁻¹] and volumetric flow [L³ T⁻¹] via fluid density (ρ).
Q = ṁ / ρ
-
1. Normalize Input to SI Base Unit (kg/s):
ṁ = 1 L/min × 1.66666667 × 10⁻⁵ = 1.66666667 × 10⁻⁵ kg/s -
2. Apply Engineering Parameter (ρ):
Selected condition: Water (20°C / Standard Ambient) at ρ = 998.2 kg/m³ -
3. Execute Governing Physical Law in SI Units:
Q = ṁ / ρ = (1.66666667 × 10⁻⁵) ÷ (998.2) = 1.669672 × 10⁻⁸ m³/s -
4. Convert to Standard Engineering Units:
• GPM: 1.669672 × 10⁻⁸ × 15850.3231 = 0.0002646 GPM (US Gallons per Minute) • CFM: 1.669672 × 10⁻⁸ × 2118.88 = 3.5378 × 10⁻⁵ CFM (Cubic Feet per Minute) • m³/h: 1.669672 × 10⁻⁸ × 3600 = 6.0108 × 10⁻⁵ m³/h (Cubic Meters per Hour) • L/min: 1.669672 × 10⁻⁸ × 60000 = 0.001002 L/min (Liters per Minute) • L/s: 1.669672 × 10⁻⁸ × 1000 = 1.6697 × 10⁻⁵ L/s (Liters per Second) • ft³/h: 1.669672 × 10⁻⁸ × 127132.8002 = 0.0021 ft³/h (Cubic Feet per Hour)
| Engineering Substance / Operating Standard | Parameter Value (kg/m³) | Reference State / Condition | Typical Industrial & Engineering Application |
|---|---|---|---|
| Water (20°C / Standard Ambient) | 998.2 |
20°C (68°F), 1 atm | Hydronic HVAC & cooling water (NIST) |
| Water (4°C / Maximum Density) | 1000 |
4°C (39.2°F), 1 atm | Pure metrology reference standard (SG = 1.0) |
| Water (100°C / Saturated Liquid) | 958.4 |
100°C (212°F), 1 atm | Boiler condensate returns & district hot water |
| Saturated Steam (100°C, 1 atm) | 0.5977 |
100°C, 1.01325 bar | Boiler steam piping & relief headers (IAPWS-97) |
| Air (Standard Ambient / NTP 20°C) | 1.204 |
20°C (68°F), 101.325 kPa (ISO 5011) | Compressor SCFM rating, blower sizing & HVAC duct air |
| Air at STP (0°C, 1 atm) | 1.292 |
0°C (32°F), 101.325 kPa (IUPAC) | Standard European gas metering & chemical plant feeds |
| Diesel Fuel (EN 590 / No. 2-D, 20°C) | 832 |
20°C (68°F), ASTM D975 / EN 590 | Engine fuel telemetry, BSFC dyno & generator consumption |
| Gasoline / Petrol (ASTM D4814, 15°C) | 740 |
15°C (59°F), ASTM D4814 | Automotive port & direct fuel injector calibrations |
| Natural Gas / Methane (STP: 0°C, 1 atm) | 0.717 |
0°C, 1 atm (Pure CH₄ approximation) | Gas turbine firing rate & burner pipeline supply |
| Engine Lubricating Oil (SAE 30, 20°C) | 885 |
20°C, typical kinematic grade 100 cSt | Engine lube circuits, turbo feed lines & cooling loops |
| Hydraulic Oil (ISO VG 46, 20°C) | 870 |
20°C, mineral hydraulic fluid | Hydraulic power packs, cylinder pump flows & servo valves |