Skip to main content

Kilocalories (th)/hour/meter/°C to Kilowatts/meter/kelvin Converter (kcal (th)/(h·m·°C) to kW/(m·K))

Rate this converter 0 of 0 ratings
Instant calculation with 0ms overhead
Popular Converters
Live Conversion • ISO 80000-5:2019 Certified
1 Kilocalorie (th)/hour/meter/°C = 0.001162222 Kilowatt/meter/kelvin
1 kcal (th)/(h·m·°C) = 0.00116222 kW/(m·K) • 1 kW/(m·K) = 860.420815 kcal (th)/(h·m·°C)
Kilocalorie (th)/hour/meter/°C to Kilowatt/meter/kelvin: One Kilocalorie (th)/hour/meter/°C is equal to 0.001162222 Kilowatts/meter/kelvin.
Certified Authority Value
0.00116222
kW/(m·K)
Exact: 1 kW/(m·K) ≡ 860.420814612 kcal (th)/(h·m·°C)
kcal (th)/(h·m·°C)
kcal (th)/(h·m·°C)
kW/(m·K)
kW/(m·K) 0.001162222
Quick Values:
Conversion Formula
To convert Kilocalorie (th)/hour/meter/°C to Kilowatt/meter/kelvin, multiply by 0.001162222
kcal (th)/(h·m·°C) × 0.001162222 = kW/(m·K)

Calculation: 1 kcal (th)/(h·m·°C) × 0.001162222 = 0.001162222 kW/(m·K)

Common Kilocalorie (th)/hour/meter/°C to Kilowatt/meter/kelvin Calculations

Quick-lookup reference table showing calculated equivalents for standard increments between Kilocalorie (th)/hour/meter/°C (kcal (th)/(h·m·°C)) and Kilowatt/meter/kelvin (kW/(m·K)).

Tap any row to calculate
Kilocalorie (th)/hour/meter/°C to Kilowatt/meter/kelvin: Primary Direct Table (15 Steps)
Kilocalorie (th)/hour/meter/°C to Kilowatt/meter/kelvin Conversion Reference Table
Conversion & Equivalent Value Scientific Notation
0.001 kcal (th)/(h·m·°C) 1.162222 × 10⁻⁶ kW/(m·K) 1.162 × 10⁻⁶
0.01 kcal (th)/(h·m·°C) 1.162222 × 10⁻⁵ kW/(m·K) 1.162 × 10⁻⁵
0.1 kcal (th)/(h·m·°C) 0.000116222 kW/(m·K) 1.162 × 10⁻⁴
0.5 kcal (th)/(h·m·°C) 0.000581111 kW/(m·K) 5.811 × 10⁻⁴
1 kcal (th)/(h·m·°C) 0.00116222 kW/(m·K) 1.162 × 10⁻³
2 kcal (th)/(h·m·°C) 0.00232444 kW/(m·K) 2.324 × 10⁻³
5 kcal (th)/(h·m·°C) 0.00581111 kW/(m·K) 5.811 × 10⁻³
10 kcal (th)/(h·m·°C) 0.0116222 kW/(m·K) 1.162 × 10⁻²
20 kcal (th)/(h·m·°C) 0.0232444 kW/(m·K) 2.324 × 10⁻²
25 kcal (th)/(h·m·°C) 0.0290556 kW/(m·K) 2.906 × 10⁻²
50 kcal (th)/(h·m·°C) 0.0581111 kW/(m·K) 5.811 × 10⁻²
100 kcal (th)/(h·m·°C) 0.116222 kW/(m·K) 1.162 × 10⁻¹
250 kcal (th)/(h·m·°C) 0.290556 kW/(m·K) 2.906 × 10⁻¹
500 kcal (th)/(h·m·°C) 0.581111 kW/(m·K) 5.811 × 10⁻¹
1000 kcal (th)/(h·m·°C) 1.162222 kW/(m·K) 1.162 × 10⁰
Kilowatt/meter/kelvin to Kilocalorie (th)/hour/meter/°C: Reciprocal Summary
Kilowatt/meter/kelvin to Kilocalorie (th)/hour/meter/°C Conversion Reference Table
Reciprocal & Equivalent Value Scientific Notation
1 kW/(m·K) 860.420815 kcal (th)/(h·m·°C) 8.604 × 10²
5 kW/(m·K) 4302.104073 kcal (th)/(h·m·°C) 4.302 × 10³
10 kW/(m·K) 8604.208146 kcal (th)/(h·m·°C) 8.604 × 10³
50 kW/(m·K) 43021.040731 kcal (th)/(h·m·°C) 4.302 × 10⁴
100 kW/(m·K) 86042.081461 kcal (th)/(h·m·°C) 8.604 × 10⁴

Real-World Context & Everyday Benchmarks

Tap to load into converter

To help contextualize these units in everyday life, science, and engineering, here are verified real-world reference points for Kilocalorie (th)/hour/meter/°C (kcal (th)/(h·m·°C)) and Kilowatt/meter/kelvin (kW/(m·K)):

Kilocalorie (th)/hour/meter/°C References:

  • Stationary atmospheric dry air thermal conductivity at sea level 0.022371 kcal (th)/(h·m·°C)
  • Commercial fiberglass building insulation batt thermal conductivity 0.034417 kcal (th)/(h·m·°C)
  • Liquid drinking water thermal conductivity at room temperature 0.516252 kcal (th)/(h·m·°C)
  • Architectural structural concrete wall thermal conductivity 1.2906 kcal (th)/(h·m·°C)

Kilowatt/meter/kelvin References:

  • Industrial high-temperature heat pipe ultra-conductive core 20 kW/(m·K)
  • Graphene monocrystal in-plane acoustic phonon conductivity 4 kW/(m·K)
ISQ Dimension: [M L T⁻³ Θ⁻¹] Coherent SI Unit: watt per meter kelvin (W/(m·K)) Thermodynamics & Heat Transfer

How to Convert Kilocalorie (th)/hour/meter/°C to Kilowatt/meter/kelvin

Converting Kilocalorie (th)/hour/meter/°C (kcal (th)/(h·m·°C)) to Kilowatt/meter/kelvin (kW/(m·K)) is a core calculation in Thermal Conductivity, which measures a material's intrinsic capacity to conduct and transfer heat through microscopic collisions. Because Kilowatt/meter/kelvin is a broader physical scale than Kilocalorie (th)/hour/meter/°C, converting from kcal (th)/(h·m·°C) to kW/(m·K) condenses the numerical figure. It takes 860.420815 Kilocalorie (th)/hour/meter/°C to equal a single Kilowatt/meter/kelvin (1 kcal (th)/(h·m·°C) = 0.00116222 kW/(m·K)). To convert any quantity, multiply by 0.00116222 (or divide by 860.420815).

Direct Factor1 kcal (th)/(h·m·°C) = 0.00116222 kW/(m·K)
Inverse Ratio1 kW/(m·K) = 860.420815 kcal (th)/(h·m·°C)
Conversion ScaleDirect Proportional Magnitude Compression
First-Principles SI Derivation ProofNIST SP 811 / ISO 80000 Compliance

Mathematical Conversion Derivation via Coherent SI Base Unit

Under the International System of Quantities (ISQ), dimensional conversion between non-SI units is rigorously resolved by bridging through the coherent SI base unit (watt per meter kelvin (W/(m·K))) without arbitrary rounding:

Vtarget=Vsource×(ksource→SIktarget→SI)V_{\text{target}} = V_{\text{source}} \times \left( \frac{k_{\text{source} \to \text{SI}}}{k_{\text{target} \to \text{SI}}} \right)
Universal Dimensional Conversion Law (ISO 80000 / NIST SP 811)
1. Source SI Bridge (ksource):1 kcal (th)/(h·m·°C) = 1.162222 watt per meter kelvin (W/(m·K))
2. Target SI Bridge (ktarget):1 kW/(m·K) = 1000 watt per meter kelvin (W/(m·K))
Step-by-step substitution for Kilocalorie (th)/hour/meter/°C → Kilowatt/meter/kelvin:V(kW/(m·K)) = V(kcal (th)/(h·m·°C)) × ( 1.162222 / 1000 ) = V(kcal (th)/(h·m·°C)) × 0.00116222
Mathematical FormulaValue in Kilowatt/meter/kelvin = Value in Kilocalorie (th)/hour/meter/°C × 0.001162222Direct computational formula applied for standard conversion.
Worked Example

Converting 36 kcal (th)/(h·m·°C) yields an exact output of 0.04184 kW/(m·K) in Kilowatt/meter/kelvin. Under higher industrial throughput, 5000 kcal (th)/(h·m·°C) translates to 5.81111 kW/(m·K).

Inverse check: 1 kW/(m·K) = 860.420815 kcal (th)/(h·m·°C).

Understanding Kilocalorie (th)/hour/meter/°C and Kilowatt/meter/kelvin

Kilocalorie (th)/hour/meter/°C

kcal (th)/(h·m·°C)
SI Multiple

A Kilocalorie (th)/hour/meter/°C (kcal (th)/(h·m·°C)) is a decimal multiple of the SI-derived unit for thermal conductivity.

Applications & Practical Context

In practical thermal conductivity terms, a stationary atmospheric dry air thermal conductivity at sea level equals 0.022371 kcal (th)/(h·m·°C), a commercial fiberglass building insulation batt thermal conductivity equals 0.034417 kcal (th)/(h·m·°C), a liquid drinking water thermal conductivity at room temperature equals 0.516252 kcal (th)/(h·m·°C).

Physical Setup

A physical magnitude of 1 kcal (th)/(h·m·°C) corresponds to 1.162222 W/(m·K) in standard SI measurement.

Conversion to SI Unit: watt per meter kelvin (W/(m·K))
1 kcal (th)/(h·m·°C) = 1.162222 W/(m·K)

Kilowatt/meter/kelvin

kW/(m·K)
SI Multiple

A Kilowatt/meter/kelvin (kW/(m·K)) is a decimal multiple of the SI-derived unit for thermal conductivity.

Applications & Practical Context

In practical thermal conductivity terms, a industrial high-temperature heat pipe ultra-conductive core equals 20 kW/(m·K), a graphene monocrystal in-plane acoustic phonon conductivity equals 4 kW/(m·K).

Physical Setup

A physical magnitude of 1 kW/(m·K) corresponds to 1000 W/(m·K) in standard SI measurement.

Conversion to SI Unit: watt per meter kelvin (W/(m·K))
1 kW/(m·K) = 1000 W/(m·K)

Domain Metrology & Engineering Applications

Governing Law & Equation

Fourier's Law of Heat Conduction (q = -k · ∇T)

Measurement Instrumentation

Rigorously quantified in laboratory and field settings using guarded hot plate apparatus (ASTM C177), laser flash thermal diffusivity analyzers, and transient plane source (TPS) sensors.

Primary Industry Sectors

Applied across thermal interface material (TIM) development, architectural insulation manufacturing, aerospace heat shield design, and refractory ceramics under international metrology standard ISO 80000-5:2019, ASTM C177.

Institutional Metrology & Standard Authority:

Formulas, conversion coefficients, and base definitions on this page strictly adhere to the ISO 80000-5:2019, ASTM C177 and the BIPM SI Brochure (9th Edition). Governed by Fourier's Law of Heat Conduction (q = -k · ∇T) under ISO 80000 dimensional vector [M L T⁻³ Θ⁻¹].

Multi-Variable Engineering Bridge Heat Transfer & Conduction Physics

Thermal Conductivity to Heat Flux Density Bridge (W/m² • kW/m² • BTU/(h·ft²) • cal/(s·cm²))

Calculate Fourier conduction heat flux q" = k × ∇T across building envelopes and industrial heat exchangers, bridging thermal conductivity [M L T⁻³ Θ⁻¹] with heat flux density [M T⁻³].

q" = k × ∇T
Vector: [W/(m·K)] × [K/m] → [W/m²]
Live Calculated Bridge Equivalent:
1 kcal (th)/(h·m·°C) at Insulated Wall Core (20K across 0.1m = 200 K/m) = 232.4444 W/m²
Equals 0.2324 kW/m² • 73.6845 BTU/(h·ft²) • 0.00555184 cal/(s·cm²)
SI Heat Flux
232.4444
W/m²
Watts per Square Meter
Solar / Combustion
0.2324
kW/m²
Kilowatts per Square Meter
US Building Envelope
73.6845
BTU/(h·ft²)
BTU per Hour Sq. Foot
CGS Thermal
0.00555184
cal/(s·cm²)
Calories per Second Sq. Cm
Meteorology
0.3332
Ly/min
Langley per Minute
Furnace Flux
0.00023244
MW/m²
Megawatts per Square Meter
  1. 1. Normalize Input to SI Base Unit (W/(m·K)):
    k = 1 kcal (th)/(h·m·°C) × 1.162222 = 1.162222 W/(m·K)
  2. 2. Apply Engineering Parameter (∇T):
    Selected condition: Insulated Wall Core (20K across 0.1m = 200 K/m) at ∇T = 200 K/m
  3. 3. Execute Governing Physical Law in SI Units:
    q" = k × ∇T = (1.162222 W/(m·K)) × (200 K/m) = 232.4444 W/m²
  4. 4. Convert to Standard Engineering Units:
    • W/m²: 232.4444 × 1 = 232.4444 W/m² (Watts per Square Meter) • kW/m²: 232.4444 × 0.001 = 0.2324 kW/m² (Kilowatts per Square Meter) • BTU/(h·ft²): 232.4444 × 0.317 = 73.6845 BTU/(h·ft²) (BTU per Hour Sq. Foot) • cal/(s·cm²): 232.4444 × 2.3885 × 10⁻⁵ = 0.00555184 cal/(s·cm²) (Calories per Second Sq. Cm) • Ly/min: 232.4444 × 0.001433 = 0.3332 Ly/min (Langley per Minute) • MW/m²: 232.4444 × 1 × 10⁻⁶ = 0.00023244 MW/m² (Megawatts per Square Meter)
Explore Full Heat Flux Density Converter →
Engineering Substance / Operating Standard Parameter Value (K/m) Reference State / Condition Typical Industrial & Engineering Application
Insulated Wall Core (20K across 0.1m = 200 K/m) 200 200 K/m Standard residential fiberglass/mineral wool batt
Solid Brick Masonry (25K across 0.25m = 100 K/m) 100 100 K/m Architectural structural brick veneer wall
Steam Boiler Tube Wall (100K across 0.005m = 20,000 K/m) 20000 20,000 K/m Carbon steel heat recovery steam boiler tube
CPU Copper Heat Spreader (30K across 0.002m = 15,000 K/m) 15000 15,000 K/m Semiconductor thermal interface heat spreader
Embed
Need this Kilocalorie (th)/hour/meter/°C to Kilowatt/meter/kelvin calculator on your website, lab portal, or research blog?
Free HTML Widget 100% Responsive Zero Cookie Tracking
Notice a calculation discrepancy, rounding error, or glitch?
Help us maintain 100% scientific precision and report any issues directly to engineering.

Frequently Asked Questions

There are exactly 0.001162222 kilowatts/meter/kelvin (kW/(m·K)) in 1 kilocalorie (th)/hour/meter/°c (kcal (th)/(h·m·°C)). To calculate larger amounts manually, simply multiply your total number of kilocalories (th)/hour/meter/°c by the conversion multiplier of 0.001162222.

The mathematical formula to convert kilocalories (th)/hour/meter/°c to kilowatts/meter/kelvin is: [value] * 0.001162222 = kilowatts/meter/kelvin. Rather than doing the math manually, you can use our high-precision online calculator to process this exact equation instantly without rounding errors.

To perform the reverse calculation from kilowatts/meter/kelvin back to kilocalories (th)/hour/meter/°c, you must divide your starting value by 0.001162222. Our bidirectional tool automatically computes this inverse equation the moment you type into the kilowatt/meter/kelvin input field.

1 Kilowatt/meter/kelvin is larger than 1 Kilocalorie (th)/hour/meter/°C. Specifically, 1 Kilocalorie (th)/hour/meter/°C equals 0.001162222 kilowatts/meter/kelvin, meaning 1 Kilowatt/meter/kelvin is 860.4208 times larger than 1 Kilocalorie (th)/hour/meter/°C (a difference of 2.93 orders of magnitude). Expressing measurements in kilocalories (th)/hour/meter/°c requires a larger numerical value to represent the equivalent physical magnitude.

Under standard international measurement guidelines, 1 Kilocalorie (th)/hour/meter/°C converts to 0.001162222 kilowatts/meter/kelvin. Precise numerical conversion factors ensure consistency across laboratory, engineering, and field data.