Skip to main content

Calories (th)/minute/square centimeter to Calories (th)/second/square centimeter Converter (cal (th)/(min·cm²) to cal (th)/(s·cm²))

Rate this converter 0 of 0 ratings
Instant calculation with 0ms overhead
Popular Converters
Live Conversion • ISO 80000-5:2019 Certified
1 Calorie (th)/minute/square centimeter = 0.016666718 Calorie (th)/second/square centimeter
1 cal (th)/(min·cm²) = 0.0166667 cal (th)/(s·cm²) • 1 cal (th)/(s·cm²) = 59.999815 cal (th)/(min·cm²)
Calorie (th)/minute/square centimeter to Calorie (th)/second/square centimeter: One Calorie (th)/minute/square centimeter is equal to 0.016666718 Calories (th)/second/square centimeter.
Certified Authority Value
0.01666672
cal (th)/(s·cm²)
Exact: 1 cal (th)/(s·cm²) ≡ 59.9998152 cal (th)/(min·cm²)
cal (th)/(min·cm²)
cal (th)/(min·cm²)
cal (th)/(s·cm²)
cal (th)/(s·cm²) 0.016666718
Quick Values:
Conversion Formula
To convert Calorie (th)/minute/square centimeter to Calorie (th)/second/square centimeter, multiply by 0.016666718
cal (th)/(min·cm²) × 0.016666718 = cal (th)/(s·cm²)

Calculation: 1 cal (th)/(min·cm²) × 0.016666718 = 0.016666718 cal (th)/(s·cm²)

Common Calorie (th)/minute/square centimeter to Calorie (th)/second/square centimeter Calculations

Quick-lookup reference table showing calculated equivalents for standard increments between Calorie (th)/minute/square centimeter (cal (th)/(min·cm²)) and Calorie (th)/second/square centimeter (cal (th)/(s·cm²)).

Tap any row to calculate
Calorie (th)/minute/square centimeter to Calorie (th)/second/square centimeter: Primary Direct Table (15 Steps)
Calorie (th)/minute/square centimeter to Calorie (th)/second/square centimeter Conversion Reference Table
Conversion & Equivalent Value Scientific Notation
0.001 cal (th)/(min·cm²) 1.666672 × 10⁻⁵ cal (th)/(s·cm²) 1.667 × 10⁻⁵
0.01 cal (th)/(min·cm²) 0.000166667 cal (th)/(s·cm²) 1.667 × 10⁻⁴
0.1 cal (th)/(min·cm²) 0.00166667 cal (th)/(s·cm²) 1.667 × 10⁻³
0.5 cal (th)/(min·cm²) 0.00833336 cal (th)/(s·cm²) 8.333 × 10⁻³
1 cal (th)/(min·cm²) 0.0166667 cal (th)/(s·cm²) 1.667 × 10⁻²
2 cal (th)/(min·cm²) 0.0333334 cal (th)/(s·cm²) 3.333 × 10⁻²
5 cal (th)/(min·cm²) 0.0833336 cal (th)/(s·cm²) 8.333 × 10⁻²
10 cal (th)/(min·cm²) 0.166667 cal (th)/(s·cm²) 1.667 × 10⁻¹
20 cal (th)/(min·cm²) 0.333334 cal (th)/(s·cm²) 3.333 × 10⁻¹
25 cal (th)/(min·cm²) 0.416668 cal (th)/(s·cm²) 4.167 × 10⁻¹
50 cal (th)/(min·cm²) 0.833336 cal (th)/(s·cm²) 8.333 × 10⁻¹
100 cal (th)/(min·cm²) 1.666672 cal (th)/(s·cm²) 1.667 × 10⁰
250 cal (th)/(min·cm²) 4.16668 cal (th)/(s·cm²) 4.167 × 10⁰
500 cal (th)/(min·cm²) 8.333359 cal (th)/(s·cm²) 8.333 × 10⁰
1000 cal (th)/(min·cm²) 16.666718 cal (th)/(s·cm²) 1.667 × 10¹
Calorie (th)/second/square centimeter to Calorie (th)/minute/square centimeter: Reciprocal Summary
Calorie (th)/second/square centimeter to Calorie (th)/minute/square centimeter Conversion Reference Table
Reciprocal & Equivalent Value Scientific Notation
1 cal (th)/(s·cm²) 59.999815 cal (th)/(min·cm²) 6 × 10¹
5 cal (th)/(s·cm²) 299.999076 cal (th)/(min·cm²) 3 × 10²
10 cal (th)/(s·cm²) 599.998152 cal (th)/(min·cm²) 6 × 10²
50 cal (th)/(s·cm²) 2999.99076 cal (th)/(min·cm²) 3 × 10³
100 cal (th)/(s·cm²) 5999.98152 cal (th)/(min·cm²) 6 × 10³

Real-World Context & Everyday Benchmarks

Tap to load into converter

To help contextualize these units in everyday life, science, and engineering, here are verified real-world reference points for Calorie (th)/minute/square centimeter (cal (th)/(min·cm²)) and Calorie (th)/second/square centimeter (cal (th)/(s·cm²)):

Calorie (th)/minute/square centimeter References:

  • Midday solar insolation measured in thermochemical calories 1.43 cal (th)/(min·cm²)

Calorie (th)/second/square centimeter References:

  • Propane flame direct impingement surface heat flux 2.5 cal (th)/(s·cm²)
ISQ Dimension: [M T⁻³] Coherent SI Unit: watt per square meter (W/m²) Thermodynamics & Heat Transfer

How to Convert Calorie (th)/minute/square centimeter to Calorie (th)/second/square centimeter

Converting Calorie (th)/minute/square centimeter (cal (th)/(min·cm²)) to Calorie (th)/second/square centimeter (cal (th)/(s·cm²)) is a core calculation in Heat Flux Density, which measures the rate of thermal energy transfer radiating or conducting through a unit area per second. Because Calorie (th)/second/square centimeter is a broader physical scale than Calorie (th)/minute/square centimeter, converting from cal (th)/(min·cm²) to cal (th)/(s·cm²) condenses the numerical figure. It takes 59.999815 Calorie (th)/minute/square centimeter to equal a single Calorie (th)/second/square centimeter (1 cal (th)/(min·cm²) = 0.0166667 cal (th)/(s·cm²)). To convert any quantity, multiply by 0.0166667 (or divide by 59.999815).

Direct Factor1 cal (th)/(min·cm²) = 0.0166667 cal (th)/(s·cm²)
Inverse Ratio1 cal (th)/(s·cm²) = 59.999815 cal (th)/(min·cm²)
Conversion ScaleDirect Proportional Magnitude Compression
First-Principles SI Derivation ProofNIST SP 811 / ISO 80000 Compliance

Mathematical Conversion Derivation via Coherent SI Base Unit

Under the International System of Quantities (ISQ), dimensional conversion between non-SI units is rigorously resolved by bridging through the coherent SI base unit (watt per square meter (W/m²)) without arbitrary rounding:

Vtarget=Vsource×(ksource→SIktarget→SI)V_{\text{target}} = V_{\text{source}} \times \left( \frac{k_{\text{source} \to \text{SI}}}{k_{\text{target} \to \text{SI}}} \right)
Universal Dimensional Conversion Law (ISO 80000 / NIST SP 811)
1. Source SI Bridge (ksource):1 cal (th)/(min·cm²) = 697.335481 watt per square meter (W/m²)
2. Target SI Bridge (ktarget):1 cal (th)/(s·cm²) = 41840 watt per square meter (W/m²)
Step-by-step substitution for Calorie (th)/minute/square centimeter → Calorie (th)/second/square centimeter:V(cal (th)/(s·cm²)) = V(cal (th)/(min·cm²)) × ( 697.335481 / 41840 ) = V(cal (th)/(min·cm²)) × 0.0166667
Mathematical FormulaValue in Calorie (th)/second/square centimeter = Value in Calorie (th)/minute/square centimeter × 0.016666718Direct computational formula applied for standard conversion.
Worked Example

For an engineering input of 75 cal (th)/(min·cm²), applying the conversion factor yields exactly 1.250004 cal (th)/(s·cm²). At larger operational scale, 10000 Calorie (th)/minute/square centimeter corresponds to 166.66718 cal (th)/(s·cm²).

Inverse check: 1 cal (th)/(s·cm²) = 59.999815 cal (th)/(min·cm²).

Understanding Calorie (th)/minute/square centimeter and Calorie (th)/second/square centimeter

Calorie (th)/minute/square centimeter

cal (th)/(min·cm²)
Standard Unit

A Calorie (th)/minute/square centimeter (cal (th)/(min·cm²)) is a recognized unit for heat flux density.

Applications & Practical Context

In practical heat flux density terms, a midday solar insolation measured in thermochemical calories equals 1.43 cal (th)/(min·cm²).

Physical Setup

A physical magnitude of 1 cal (th)/(min·cm²) corresponds to 697.335481 W/m² in standard SI measurement.

Conversion to SI Unit: watt per square meter (W/m²)
1 cal (th)/(min·cm²) = 697.335481 W/m²

Calorie (th)/second/square centimeter

cal (th)/(s·cm²)
Standard Unit

A Calorie (th)/second/square centimeter (cal (th)/(s·cm²)) is a recognized unit for heat flux density.

Applications & Practical Context

In practical heat flux density terms, a propane flame direct impingement surface heat flux equals 2.5 cal (th)/(s·cm²).

Physical Setup

A physical magnitude of 1 cal (th)/(s·cm²) corresponds to 41840 W/m² in standard SI measurement.

Conversion to SI Unit: watt per square meter (W/m²)
1 cal (th)/(s·cm²) = 41840 W/m²

Domain Metrology & Engineering Applications

Governing Law & Equation

Thermal Transmission Flux (q = Q̇ / A)

Measurement Instrumentation

Rigorously quantified in laboratory and field settings using Schmidt-Boelter heat flux gauges, differential thermopile foil transducers, and calibrated Gardon radiant gauges.

Primary Industry Sectors

Applied across rocket nozzle combustion chamber analysis, fire resistance testing (ASTM E119), furnace wall heat loss auditing, and hypersonic aerothermal design under international metrology standard ISO 80000-5:2019, ASME PTC 19.3.

Institutional Metrology & Standard Authority:

Formulas, conversion coefficients, and base definitions on this page strictly adhere to the ISO 80000-5:2019, ASME PTC 19.3 and the BIPM SI Brochure (9th Edition). Governed by Thermal Transmission Flux (q = Q̇ / A) under ISO 80000 dimensional vector [M T⁻³].

Multi-Variable Engineering Bridge Thermal Radiation & Power Dissipation

Heat Flux Density to Total Thermal Power Bridge (Watts • Kilowatts • Megawatts • BTU/h • Horsepower)

Calculate total continuous heat dissipation power P = q" × A across surface barriers and exchangers, bridging heat flux density [M T⁻³] with thermal power [M L² T⁻³].

P = q" × A
Vector: [W/m²] × [m²] → [W]
Live Calculated Bridge Equivalent:
1 cal (th)/(min·cm²) at Industrial Hydronic Radiator Panel (8 m²) = 5578.6838 W
Equals 5.5787 kW • 0.00557868 MW • 7.4811 hp
SI Power
5578.6838
W
Watts
Grid / Utility
5.5787
kW
Kilowatts
Power Plant
0.00557868
MW
Megawatts
Mechanical Rating
7.4811
hp
Horsepower (Mechanical)
Metric Horsepower
7.5849
PS
Metric Horsepower (PS)
HVAC Thermal Rating
19035.26
BTU/h
BTU per Hour
  1. 1. Normalize Input to SI Base Unit (W/m²):
    q" = 1 cal (th)/(min·cm²) × 697.33548113 = 697.33548113 W/m²
  2. 2. Apply Engineering Parameter (A):
    Selected condition: Industrial Hydronic Radiator Panel (8 m²) at A = 8 m²
  3. 3. Execute Governing Physical Law in SI Units:
    P = q" × A = (697.33548113 W/m²) × (8 m²) = 5578.683849 W
  4. 4. Convert to Standard Engineering Units:
    • W: 5578.683849 × 1 = 5578.6838 W (Watts) • kW: 5578.683849 × 0.001 = 5.5787 kW (Kilowatts) • MW: 5578.683849 × 1 × 10⁻⁶ = 0.00557868 MW (Megawatts) • hp: 5578.683849 × 0.001341 = 7.4811 hp (Horsepower (Mechanical)) • PS: 5578.683849 × 0.00136 = 7.5849 PS (Metric Horsepower (PS)) • BTU/h: 5578.683849 × 3.4121 = 19035.26 BTU/h (BTU per Hour)
Explore Full Power Converter →
Engineering Substance / Operating Standard Parameter Value (m²) Reference State / Condition Typical Industrial & Engineering Application
Residential Window Glazing (4 m²) 4 4.0 m² Double-pane exterior window glass aperture
Industrial Hydronic Radiator Panel (8 m²) 8 8.0 m² Convective space heating radiator surface
Shell & Tube Heat Exchanger (50 m²) 50 50.0 m² Industrial process fluid cooling bundle
Power Boiler Waterwall (200 m²) 200 200.0 m² Thermal power plant steam generator wall
Embed
Need this Calorie (th)/minute/square centimeter to Calorie (th)/second/square centimeter calculator on your website, lab portal, or research blog?
Free HTML Widget 100% Responsive Zero Cookie Tracking
Notice a calculation discrepancy, rounding error, or glitch?
Help us maintain 100% scientific precision and report any issues directly to engineering.

Frequently Asked Questions

There are exactly 0.016666718 calories (th)/second/square centimeter (cal (th)/(s·cm²)) in 1 calorie (th)/minute/square centimeter (cal (th)/(min·cm²)). To calculate larger amounts manually, simply multiply your total number of calories (th)/minute/square centimeter by the conversion multiplier of 0.016666718.

The mathematical formula to convert calories (th)/minute/square centimeter to calories (th)/second/square centimeter is: [value] * 0.016666718 = calories (th)/second/square centimeter. Rather than doing the math manually, you can use our high-precision online calculator to process this exact equation instantly without rounding errors.

To perform the reverse calculation from calories (th)/second/square centimeter back to calories (th)/minute/square centimeter, you must divide your starting value by 0.016666718. Our bidirectional tool automatically computes this inverse equation the moment you type into the calorie (th)/second/square centimeter input field.

1 Calorie (th)/second/square centimeter is larger than 1 Calorie (th)/minute/square centimeter. Specifically, 1 Calorie (th)/minute/square centimeter equals 0.016666718 calories (th)/second/square centimeter, meaning 1 Calorie (th)/second/square centimeter is 59.9998 times larger than 1 Calorie (th)/minute/square centimeter (a difference of 1.78 orders of magnitude). Expressing measurements in calories (th)/minute/square centimeter requires a larger numerical value to represent the equivalent physical magnitude.

Under standard international measurement guidelines, 1 Calorie (th)/minute/square centimeter converts to 0.016666718 calories (th)/second/square centimeter. Precise numerical conversion factors ensure consistency across laboratory, engineering, and field data.