Btu (th) Feet/hour/sq. foot/°F to Calories (th)/second/cm/°C Converter (Btu (th)·ft/(h·ft²·°F) to cal (th)/(s·cm·°C))
Btu (th)·ft/(h·ft²·°F) × 0.0041337882 = cal (th)/(s·cm·°C)
Calculation: 1 Btu (th)·ft/(h·ft²·°F) × 0.0041337882 = 0.0041337882 cal (th)/(s·cm·°C)
Common BTU (th) foot/hour/sq. foot/°F to Calorie (th)/second/cm/°C Calculations
Quick-lookup reference table showing calculated equivalents for standard increments between BTU (th) foot/hour/sq. foot/°F (Btu (th)·ft/(h·ft²·°F)) and Calorie (th)/second/cm/°C (cal (th)/(s·cm·°C)).
| Conversion & Equivalent Value | Scientific Notation |
|---|---|
| 0.001 Btu (th)·ft/(h·ft²·°F) 4.133788 × 10⁻⁶ cal (th)/(s·cm·°C) | 4.134 × 10⁻⁶ |
| 0.01 Btu (th)·ft/(h·ft²·°F) 4.133788 × 10⁻⁵ cal (th)/(s·cm·°C) | 4.134 × 10⁻⁵ |
| 0.1 Btu (th)·ft/(h·ft²·°F) 0.000413379 cal (th)/(s·cm·°C) | 4.134 × 10⁻⁴ |
| 0.5 Btu (th)·ft/(h·ft²·°F) 0.00206689 cal (th)/(s·cm·°C) | 2.067 × 10⁻³ |
| 1 Btu (th)·ft/(h·ft²·°F) 0.00413379 cal (th)/(s·cm·°C) | 4.134 × 10⁻³ |
| 2 Btu (th)·ft/(h·ft²·°F) 0.00826758 cal (th)/(s·cm·°C) | 8.268 × 10⁻³ |
| 5 Btu (th)·ft/(h·ft²·°F) 0.0206689 cal (th)/(s·cm·°C) | 2.067 × 10⁻² |
| 10 Btu (th)·ft/(h·ft²·°F) 0.0413379 cal (th)/(s·cm·°C) | 4.134 × 10⁻² |
| 20 Btu (th)·ft/(h·ft²·°F) 0.0826758 cal (th)/(s·cm·°C) | 8.268 × 10⁻² |
| 25 Btu (th)·ft/(h·ft²·°F) 0.103345 cal (th)/(s·cm·°C) | 1.033 × 10⁻¹ |
| 50 Btu (th)·ft/(h·ft²·°F) 0.206689 cal (th)/(s·cm·°C) | 2.067 × 10⁻¹ |
| 100 Btu (th)·ft/(h·ft²·°F) 0.413379 cal (th)/(s·cm·°C) | 4.134 × 10⁻¹ |
| 250 Btu (th)·ft/(h·ft²·°F) 1.033447 cal (th)/(s·cm·°C) | 1.033 × 10⁰ |
| 500 Btu (th)·ft/(h·ft²·°F) 2.066894 cal (th)/(s·cm·°C) | 2.067 × 10⁰ |
| 1000 Btu (th)·ft/(h·ft²·°F) 4.133788 cal (th)/(s·cm·°C) | 4.134 × 10⁰ |
| Reciprocal & Equivalent Value | Scientific Notation |
|---|---|
| 1 cal (th)/(s·cm·°C) 241.90886 Btu (th)·ft/(h·ft²·°F) | 2.419 × 10² |
| 5 cal (th)/(s·cm·°C) 1209.544299 Btu (th)·ft/(h·ft²·°F) | 1.21 × 10³ |
| 10 cal (th)/(s·cm·°C) 2419.088598 Btu (th)·ft/(h·ft²·°F) | 2.419 × 10³ |
| 50 cal (th)/(s·cm·°C) 12095.44299 Btu (th)·ft/(h·ft²·°F) | 1.21 × 10⁴ |
| 100 cal (th)/(s·cm·°C) 24190.88598 Btu (th)·ft/(h·ft²·°F) | 2.419 × 10⁴ |
Real-World Context & Everyday Benchmarks
Tap to load into converterTo help contextualize these units in everyday life, science, and engineering, here are verified real-world reference points for BTU (th) foot/hour/sq. foot/°F (Btu (th)·ft/(h·ft²·°F)) and Calorie (th)/second/cm/°C (cal (th)/(s·cm·°C)):
BTU (th) foot/hour/sq. foot/°F References:
- Stationary atmospheric dry air thermal conductivity at sea level 0.015033 Btu (th)·ft/(h·ft²·°F)
- Commercial fiberglass building insulation batt thermal conductivity 0.023127 Btu (th)·ft/(h·ft²·°F)
- Liquid drinking water thermal conductivity at room temperature 0.346906 Btu (th)·ft/(h·ft²·°F)
- Architectural structural concrete wall thermal conductivity 0.867264 Btu (th)·ft/(h·ft²·°F)
Calorie (th)/second/cm/°C References:
- Stationary atmospheric dry air thermal conductivity at sea level 6.2E-5 cal (th)/(s·cm·°C)
- Commercial fiberglass building insulation batt thermal conductivity 9.6E-5 cal (th)/(s·cm·°C)
- Liquid drinking water thermal conductivity at room temperature 0.001434 cal (th)/(s·cm·°C)
- Architectural structural concrete wall thermal conductivity 0.003585 cal (th)/(s·cm·°C)
How to Convert BTU (th) foot/hour/sq. foot/°F to Calorie (th)/second/cm/°C
Converting BTU (th) foot/hour/sq. foot/°F (Btu (th)·ft/(h·ft²·°F)) to Calorie (th)/second/cm/°C (cal (th)/(s·cm·°C)) is a core calculation in Thermal Conductivity, which measures a material's intrinsic capacity to conduct and transfer heat through microscopic collisions. This calculation navigates the boundary between the International Metric System (SI) and British Imperial / US Customary engineering standards. In contemporary metrology, Imperial units are defined in terms of exact SI standards via international agreements—notably NIST SP 811 and the 1959 International Yard and Pound Agreement. Exactly 1 BTU (th) foot/hour/sq. foot/°F equals 0.00413379 Calorie (th)/second/cm/°C, while 1 cal (th)/(s·cm·°C) equals 241.90886 Btu (th)·ft/(h·ft²·°F).
Mathematical Conversion Derivation via Coherent SI Base Unit
Under the International System of Quantities (ISQ), dimensional conversion between non-SI units is rigorously resolved by bridging through the coherent SI base unit (watt per meter kelvin (W/(m·K))) without arbitrary rounding:
1 Btu (th)·ft/(h·ft²·°F) = 1.729577 watt per meter kelvin (W/(m·K))1 cal (th)/(s·cm·°C) = 418.4 watt per meter kelvin (W/(m·K))V(cal (th)/(s·cm·°C)) = V(Btu (th)·ft/(h·ft²·°F)) × ( 1.729577 / 418.4 ) = V(Btu (th)·ft/(h·ft²·°F)) × 0.00413379Value in Calorie (th)/second/cm/°C = Value in BTU (th) foot/hour/sq. foot/°F × 0.0041337882Direct computational formula applied for standard conversion.For an engineering input of 36 Btu (th)·ft/(h·ft²·°F), applying the conversion factor yields exactly 0.148816 cal (th)/(s·cm·°C). At larger operational scale, 5000 BTU (th) foot/hour/sq. foot/°F corresponds to 20.668941 cal (th)/(s·cm·°C).
Inverse check: 1 cal (th)/(s·cm·°C) = 241.90886 Btu (th)·ft/(h·ft²·°F).Understanding BTU (th) foot/hour/sq. foot/°F and Calorie (th)/second/cm/°C
BTU (th) foot/hour/sq. foot/°F
Btu (th)·ft/(h·ft²·°F)A BTU (th) foot/hour/sq. foot/°F (Btu (th)·ft/(h·ft²·°F)) is an imperial and US customary unit for thermal conductivity.
Applications & Practical Context
In practical thermal conductivity terms, a stationary atmospheric dry air thermal conductivity at sea level equals 0.015033 Btu (th)·ft/(h·ft²·°F), a commercial fiberglass building insulation batt thermal conductivity equals 0.023127 Btu (th)·ft/(h·ft²·°F), a liquid drinking water thermal conductivity at room temperature equals 0.346906 Btu (th)·ft/(h·ft²·°F).
A physical magnitude of 1 Btu (th)·ft/(h·ft²·°F) corresponds to 1.729577 W/(m·K) in standard SI measurement.
1 Btu (th)·ft/(h·ft²·°F) = 1.729577 W/(m·K)Calorie (th)/second/cm/°C
cal (th)/(s·cm·°C)A Calorie (th)/second/cm/°C (cal (th)/(s·cm·°C)) is a recognized unit for thermal conductivity.
Applications & Practical Context
In practical thermal conductivity terms, a stationary atmospheric dry air thermal conductivity at sea level equals 6.2 × 10⁻⁵ cal (th)/(s·cm·°C), a commercial fiberglass building insulation batt thermal conductivity equals 9.6 × 10⁻⁵ cal (th)/(s·cm·°C), a liquid drinking water thermal conductivity at room temperature equals 0.001434 cal (th)/(s·cm·°C).
A physical magnitude of 1 cal (th)/(s·cm·°C) corresponds to 418.4 W/(m·K) in standard SI measurement.
1 cal (th)/(s·cm·°C) = 418.4 W/(m·K)Domain Metrology & Engineering Applications
Fourier's Law of Heat Conduction (q = -k · ∇T)
Rigorously quantified in laboratory and field settings using guarded hot plate apparatus (ASTM C177), laser flash thermal diffusivity analyzers, and transient plane source (TPS) sensors.
Applied across thermal interface material (TIM) development, architectural insulation manufacturing, aerospace heat shield design, and refractory ceramics under international metrology standard ISO 80000-5:2019, ASTM C177.
Formulas, conversion coefficients, and base definitions on this page strictly adhere to the ISO 80000-5:2019, ASTM C177 and the BIPM SI Brochure (9th Edition). Governed by Fourier's Law of Heat Conduction (q = -k · ∇T) under ISO 80000 dimensional vector [M L T⁻³ Θ⁻¹].
Thermal Conductivity to Heat Flux Density Bridge (W/m² • kW/m² • BTU/(h·ft²) • cal/(s·cm²))
Calculate Fourier conduction heat flux q" = k × ∇T across building envelopes and industrial heat exchangers, bridging thermal conductivity [M L T⁻³ Θ⁻¹] with heat flux density [M T⁻³].
q" = k × ∇T
[W/(m·K)] × [K/m] → [W/m²]
-
1. Normalize Input to SI Base Unit (W/(m·K)):
k = 1 Btu (th)·ft/(h·ft²·°F) × 1.729577 = 1.729577 W/(m·K) -
2. Apply Engineering Parameter (∇T):
Selected condition: Insulated Wall Core (20K across 0.1m = 200 K/m) at ∇T = 200 K/m -
3. Execute Governing Physical Law in SI Units:
q" = k × ∇T = (1.729577 W/(m·K)) × (200 K/m) = 345.9154 W/m² -
4. Convert to Standard Engineering Units:
• W/m²: 345.9154 × 1 = 345.9154 W/m² (Watts per Square Meter) • kW/m²: 345.9154 × 0.001 = 0.3459 kW/m² (Kilowatts per Square Meter) • BTU/(h·ft²): 345.9154 × 0.317 = 109.6546 BTU/(h·ft²) (BTU per Hour Sq. Foot) • cal/(s·cm²): 345.9154 × 2.3885 × 10⁻⁵ = 0.00826205 cal/(s·cm²) (Calories per Second Sq. Cm) • Ly/min: 345.9154 × 0.001433 = 0.4958 Ly/min (Langley per Minute) • MW/m²: 345.9154 × 1 × 10⁻⁶ = 0.00034592 MW/m² (Megawatts per Square Meter)
| Engineering Substance / Operating Standard | Parameter Value (K/m) | Reference State / Condition | Typical Industrial & Engineering Application |
|---|---|---|---|
| Insulated Wall Core (20K across 0.1m = 200 K/m) | 200 |
200 K/m | Standard residential fiberglass/mineral wool batt |
| Solid Brick Masonry (25K across 0.25m = 100 K/m) | 100 |
100 K/m | Architectural structural brick veneer wall |
| Steam Boiler Tube Wall (100K across 0.005m = 20,000 K/m) | 20000 |
20,000 K/m | Carbon steel heat recovery steam boiler tube |
| CPU Copper Heat Spreader (30K across 0.002m = 15,000 K/m) | 15000 |
15,000 K/m | Semiconductor thermal interface heat spreader |
Frequently Asked Questions
Related BTU (th) foot/hour/sq. foot/°F and Calorie (th)/second/cm/°C Conversions
Convert BTU (th) foot/hour/sq. foot/°F to Other Units
Convert Other Units to Calorie (th)/second/cm/°C
Physically Coupled Thermodynamics & Heat Converters
Explore interconnected physical dimension converters within the Thermodynamics & Heat cluster (ISO 80000-5:2019).