Skip to main content

Btus/hour/foot/°F to Calories (thermochemical)/second/centimeter/°C Converter (Btu/(h·ft·°F) to cal/(s·cm·°C))

Rate this converter 0 of 0 ratings
Instant calculation with 0ms overhead
Popular Converters
Live Conversion • ISO 80000-5:2019 Certified
1 Btu/hour/foot/°F = 0.0041337928 Calorie/second/centimeter/°C
1 Btu/(h·ft·°F) = 0.00413379 cal/(s·cm·°C) • 1 cal/(s·cm·°C) = 241.908594 Btu/(h·ft·°F)
Btu/hour/foot/°F to Calorie/second/centimeter/°C: One Btu/hour/foot/°F is equal to 0.0041337928 Calories (thermochemical)/second/centimeter/°C.
Certified Authority Value
0.00413379
cal/(s·cm·°C)
Exact: 1 cal/(s·cm·°C) ≡ 241.908593822 Btu/(h·ft·°F)
Btu/(h·ft·°F)
Btu/(h·ft·°F)
cal/(s·cm·°C)
cal/(s·cm·°C) 0.0041337928
Quick Values:
Conversion Formula
To convert Btu/hour/foot/°F to Calorie/second/centimeter/°C, multiply by 0.0041337928
Btu/(h·ft·°F) × 0.0041337928 = cal/(s·cm·°C)

Calculation: 1 Btu/(h·ft·°F) × 0.0041337928 = 0.0041337928 cal/(s·cm·°C)

Common Btu/hour/foot/°F to Calorie/second/centimeter/°C Calculations

Quick-lookup reference table showing calculated equivalents for standard increments between Btu/hour/foot/°F (Btu/(h·ft·°F)) and Calorie/second/centimeter/°C (cal/(s·cm·°C)).

Tap any row to calculate
Btu/hour/foot/°F to Calorie/second/centimeter/°C: Primary Direct Table (15 Steps)
Btu/hour/foot/°F to Calorie/second/centimeter/°C Conversion Reference Table
Conversion & Equivalent Value Scientific Notation
0.001 Btu/(h·ft·°F) 4.133793 × 10⁻⁶ cal/(s·cm·°C) 4.134 × 10⁻⁶
0.01 Btu/(h·ft·°F) 4.133793 × 10⁻⁵ cal/(s·cm·°C) 4.134 × 10⁻⁵
0.1 Btu/(h·ft·°F) 0.000413379 cal/(s·cm·°C) 4.134 × 10⁻⁴
0.5 Btu/(h·ft·°F) 0.0020669 cal/(s·cm·°C) 2.067 × 10⁻³
1 Btu/(h·ft·°F) 0.00413379 cal/(s·cm·°C) 4.134 × 10⁻³
2 Btu/(h·ft·°F) 0.00826759 cal/(s·cm·°C) 8.268 × 10⁻³
5 Btu/(h·ft·°F) 0.020669 cal/(s·cm·°C) 2.067 × 10⁻²
10 Btu/(h·ft·°F) 0.0413379 cal/(s·cm·°C) 4.134 × 10⁻²
20 Btu/(h·ft·°F) 0.0826759 cal/(s·cm·°C) 8.268 × 10⁻²
25 Btu/(h·ft·°F) 0.103345 cal/(s·cm·°C) 1.033 × 10⁻¹
50 Btu/(h·ft·°F) 0.20669 cal/(s·cm·°C) 2.067 × 10⁻¹
100 Btu/(h·ft·°F) 0.413379 cal/(s·cm·°C) 4.134 × 10⁻¹
250 Btu/(h·ft·°F) 1.033448 cal/(s·cm·°C) 1.033 × 10⁰
500 Btu/(h·ft·°F) 2.066896 cal/(s·cm·°C) 2.067 × 10⁰
1000 Btu/(h·ft·°F) 4.133793 cal/(s·cm·°C) 4.134 × 10⁰
Calorie/second/centimeter/°C to Btu/hour/foot/°F: Reciprocal Summary
Calorie/second/centimeter/°C to Btu/hour/foot/°F Conversion Reference Table
Reciprocal & Equivalent Value Scientific Notation
1 cal/(s·cm·°C) 241.908594 Btu/(h·ft·°F) 2.419 × 10²
5 cal/(s·cm·°C) 1209.542969 Btu/(h·ft·°F) 1.21 × 10³
10 cal/(s·cm·°C) 2419.085938 Btu/(h·ft·°F) 2.419 × 10³
50 cal/(s·cm·°C) 12095.429691 Btu/(h·ft·°F) 1.21 × 10⁴
100 cal/(s·cm·°C) 24190.859382 Btu/(h·ft·°F) 2.419 × 10⁴

Real-World Context & Everyday Benchmarks

Tap to load into converter

To help contextualize these units in everyday life, science, and engineering, here are verified real-world reference points for Btu/hour/foot/°F (Btu/(h·ft·°F)) and Calorie/second/centimeter/°C (cal/(s·cm·°C)):

Btu/hour/foot/°F References:

  • Stationary atmospheric dry air thermal conductivity at sea level 0.015023 Btu/(h·ft·°F)
  • Commercial fiberglass building insulation batt thermal conductivity 0.023112 Btu/(h·ft·°F)
  • Liquid drinking water thermal conductivity at room temperature 0.346673 Btu/(h·ft·°F)
  • Architectural structural concrete wall thermal conductivity 0.866684 Btu/(h·ft·°F)

Calorie/second/centimeter/°C References:

  • Stationary atmospheric dry air thermal conductivity at sea level 6.2E-5 cal/(s·cm·°C)
  • Commercial fiberglass building insulation batt thermal conductivity 9.6E-5 cal/(s·cm·°C)
  • Liquid drinking water thermal conductivity at room temperature 0.001433 cal/(s·cm·°C)
  • Architectural structural concrete wall thermal conductivity 0.003583 cal/(s·cm·°C)
ISQ Dimension: [M L T⁻³ Θ⁻¹] Coherent SI Unit: watt per meter kelvin (W/(m·K)) Thermodynamics & Heat Transfer

How to Convert Btu/hour/foot/°F to Calorie/second/centimeter/°C

Converting Btu/hour/foot/°F (Btu/(h·ft·°F)) to Calorie/second/centimeter/°C (cal/(s·cm·°C)) is a core calculation in Thermal Conductivity, which measures a material's intrinsic capacity to conduct and transfer heat through microscopic collisions. This calculation navigates the boundary between the International Metric System (SI) and British Imperial / US Customary engineering standards. In contemporary metrology, Imperial units are defined in terms of exact SI standards via international agreements—notably NIST SP 811 and the 1959 International Yard and Pound Agreement. Exactly 1 Btu/hour/foot/°F equals 0.00413379 Calorie/second/centimeter/°C, while 1 cal/(s·cm·°C) equals 241.908594 Btu/(h·ft·°F).

Direct Factor1 Btu/(h·ft·°F) = 0.00413379 cal/(s·cm·°C)
Inverse Ratio1 cal/(s·cm·°C) = 241.908594 Btu/(h·ft·°F)
Conversion ScaleMetric SI to British Imperial / US Customary Bridge
First-Principles SI Derivation ProofNIST SP 811 / ISO 80000 Compliance

Mathematical Conversion Derivation via Coherent SI Base Unit

Under the International System of Quantities (ISQ), dimensional conversion between non-SI units is rigorously resolved by bridging through the coherent SI base unit (watt per meter kelvin (W/(m·K))) without arbitrary rounding:

Vtarget=Vsource×(ksource→SIktarget→SI)V_{\text{target}} = V_{\text{source}} \times \left( \frac{k_{\text{source} \to \text{SI}}}{k_{\text{target} \to \text{SI}}} \right)
Universal Dimensional Conversion Law (ISO 80000 / NIST SP 811)
1. Source SI Bridge (ksource):1 Btu/(h·ft·°F) = 1.730736 watt per meter kelvin (W/(m·K))
2. Target SI Bridge (ktarget):1 cal/(s·cm·°C) = 418.679819 watt per meter kelvin (W/(m·K))
Step-by-step substitution for Btu/hour/foot/°F → Calorie/second/centimeter/°C:V(cal/(s·cm·°C)) = V(Btu/(h·ft·°F)) × ( 1.730736 / 418.679819 ) = V(Btu/(h·ft·°F)) × 0.00413379
Mathematical FormulaValue in Calorie/second/centimeter/°C = Value in Btu/hour/foot/°F × 0.0041337928Direct computational formula applied for standard conversion.
Worked Example

For an engineering input of 250 Btu/(h·ft·°F), applying the conversion factor yields exactly 1.033448 cal/(s·cm·°C). At larger operational scale, 240 Btu/hour/foot/°F corresponds to 0.99211 cal/(s·cm·°C).

Inverse check: 1 cal/(s·cm·°C) = 241.908594 Btu/(h·ft·°F).

Understanding Btu/hour/foot/°F and Calorie/second/centimeter/°C

Btu/hour/foot/°F

Btu/(h·ft·°F)
Imperial / US

A Btu/hour/foot/°F (Btu/(h·ft·°F)) is an imperial and US customary unit for thermal conductivity.

Applications & Practical Context

In practical thermal conductivity terms, a stationary atmospheric dry air thermal conductivity at sea level equals 0.015023 Btu/(h·ft·°F), a commercial fiberglass building insulation batt thermal conductivity equals 0.023112 Btu/(h·ft·°F), a liquid drinking water thermal conductivity at room temperature equals 0.346673 Btu/(h·ft·°F).

Physical Setup

A physical magnitude of 1 Btu/(h·ft·°F) corresponds to 1.730736 W/(m·K) in standard SI measurement.

Conversion to SI Unit: watt per meter kelvin (W/(m·K))
1 Btu/(h·ft·°F) = 1.730736 W/(m·K)

Calorie/second/centimeter/°C

cal/(s·cm·°C)
Standard Unit

A Calorie/second/centimeter/°C (cal/(s·cm·°C)) is a recognized unit for thermal conductivity.

Applications & Practical Context

In practical thermal conductivity terms, a stationary atmospheric dry air thermal conductivity at sea level equals 6.2 × 10⁻⁵ cal/(s·cm·°C), a commercial fiberglass building insulation batt thermal conductivity equals 9.6 × 10⁻⁵ cal/(s·cm·°C), a liquid drinking water thermal conductivity at room temperature equals 0.001433 cal/(s·cm·°C).

Physical Setup

A physical magnitude of 1 cal/(s·cm·°C) corresponds to 418.679819 W/(m·K) in standard SI measurement.

Conversion to SI Unit: watt per meter kelvin (W/(m·K))
1 cal/(s·cm·°C) = 418.679819 W/(m·K)

Domain Metrology & Engineering Applications

Governing Law & Equation

Fourier's Law of Heat Conduction (q = -k · ∇T)

Measurement Instrumentation

Rigorously quantified in laboratory and field settings using guarded hot plate apparatus (ASTM C177), laser flash thermal diffusivity analyzers, and transient plane source (TPS) sensors.

Primary Industry Sectors

Applied across thermal interface material (TIM) development, architectural insulation manufacturing, aerospace heat shield design, and refractory ceramics under international metrology standard ISO 80000-5:2019, ASTM C177.

Institutional Metrology & Standard Authority:

Formulas, conversion coefficients, and base definitions on this page strictly adhere to the ISO 80000-5:2019, ASTM C177 and the BIPM SI Brochure (9th Edition). Governed by Fourier's Law of Heat Conduction (q = -k · ∇T) under ISO 80000 dimensional vector [M L T⁻³ Θ⁻¹].

Multi-Variable Engineering Bridge Heat Transfer & Conduction Physics

Thermal Conductivity to Heat Flux Density Bridge (W/m² • kW/m² • BTU/(h·ft²) • cal/(s·cm²))

Calculate Fourier conduction heat flux q" = k × ∇T across building envelopes and industrial heat exchangers, bridging thermal conductivity [M L T⁻³ Θ⁻¹] with heat flux density [M T⁻³].

q" = k × ∇T
Vector: [W/(m·K)] × [K/m] → [W/m²]
Live Calculated Bridge Equivalent:
1 Btu/(h·ft·°F) at Insulated Wall Core (20K across 0.1m = 200 K/m) = 346.1471 W/m²
Equals 0.3461 kW/m² • 109.7281 BTU/(h·ft²) • 0.00826758 cal/(s·cm²)
SI Heat Flux
346.1471
W/m²
Watts per Square Meter
Solar / Combustion
0.3461
kW/m²
Kilowatts per Square Meter
US Building Envelope
109.7281
BTU/(h·ft²)
BTU per Hour Sq. Foot
CGS Thermal
0.00826758
cal/(s·cm²)
Calories per Second Sq. Cm
Meteorology
0.4961
Ly/min
Langley per Minute
Furnace Flux
0.00034615
MW/m²
Megawatts per Square Meter
  1. 1. Normalize Input to SI Base Unit (W/(m·K)):
    k = 1 Btu/(h·ft·°F) × 1.73073561 = 1.73073561 W/(m·K)
  2. 2. Apply Engineering Parameter (∇T):
    Selected condition: Insulated Wall Core (20K across 0.1m = 200 K/m) at ∇T = 200 K/m
  3. 3. Execute Governing Physical Law in SI Units:
    q" = k × ∇T = (1.73073561 W/(m·K)) × (200 K/m) = 346.147123 W/m²
  4. 4. Convert to Standard Engineering Units:
    • W/m²: 346.147123 × 1 = 346.1471 W/m² (Watts per Square Meter) • kW/m²: 346.147123 × 0.001 = 0.3461 kW/m² (Kilowatts per Square Meter) • BTU/(h·ft²): 346.147123 × 0.317 = 109.7281 BTU/(h·ft²) (BTU per Hour Sq. Foot) • cal/(s·cm²): 346.147123 × 2.3885 × 10⁻⁵ = 0.00826758 cal/(s·cm²) (Calories per Second Sq. Cm) • Ly/min: 346.147123 × 0.001433 = 0.4961 Ly/min (Langley per Minute) • MW/m²: 346.147123 × 1 × 10⁻⁶ = 0.00034615 MW/m² (Megawatts per Square Meter)
Explore Full Heat Flux Density Converter →
Engineering Substance / Operating Standard Parameter Value (K/m) Reference State / Condition Typical Industrial & Engineering Application
Insulated Wall Core (20K across 0.1m = 200 K/m) 200 200 K/m Standard residential fiberglass/mineral wool batt
Solid Brick Masonry (25K across 0.25m = 100 K/m) 100 100 K/m Architectural structural brick veneer wall
Steam Boiler Tube Wall (100K across 0.005m = 20,000 K/m) 20000 20,000 K/m Carbon steel heat recovery steam boiler tube
CPU Copper Heat Spreader (30K across 0.002m = 15,000 K/m) 15000 15,000 K/m Semiconductor thermal interface heat spreader
Embed
Need this Btu/hour/foot/°F to Calorie/second/centimeter/°C calculator on your website, lab portal, or research blog?
Free HTML Widget 100% Responsive Zero Cookie Tracking
Notice a calculation discrepancy, rounding error, or glitch?
Help us maintain 100% scientific precision and report any issues directly to engineering.

Frequently Asked Questions

There are exactly 0.0041337928 calories (thermochemical)/second/centimeter/°c (cal/(s·cm·°C)) in 1 btu/hour/foot/°f (Btu/(h·ft·°F)). To calculate larger amounts manually, simply multiply your total number of btus/hour/foot/°f by the conversion multiplier of 0.0041337928.

The mathematical formula to convert btus/hour/foot/°f to calories (thermochemical)/second/centimeter/°c is: [value] * 0.0041337928 = calories (thermochemical)/second/centimeter/°c. Rather than doing the math manually, you can use our high-precision online calculator to process this exact equation instantly without rounding errors.

To perform the reverse calculation from calories (thermochemical)/second/centimeter/°c back to btus/hour/foot/°f, you must divide your starting value by 0.0041337928. Our bidirectional tool automatically computes this inverse equation the moment you type into the calorie/second/centimeter/°c input field.

1 Calorie/second/centimeter/°C is larger than 1 Btu/hour/foot/°F. Specifically, 1 Btu/hour/foot/°F equals 0.0041337928 calories (thermochemical)/second/centimeter/°c, meaning 1 Calorie/second/centimeter/°C is 241.9086 times larger than 1 Btu/hour/foot/°F (a difference of 2.38 orders of magnitude). Expressing measurements in btus/hour/foot/°f requires a larger numerical value to represent the equivalent physical magnitude.

Under standard international measurement guidelines, 1 Btu/hour/foot/°F converts to 0.0041337928 calories (thermochemical)/second/centimeter/°c. Precise numerical conversion factors ensure consistency across laboratory, engineering, and field data.