Btu (it) Inches/hour/sq. foot/°F to Btu (th) Inches/second/sq. foot/°F Converter (Btu·in/(h·ft²·°F) to Btu (th)·in/(s·ft²·°F))
Btu·in/(h·ft²·°F) × 0.00027796367 = Btu (th)·in/(s·ft²·°F)
Calculation: 1 Btu·in/(h·ft²·°F) × 0.00027796367 = 0.00027796367 Btu (th)·in/(s·ft²·°F)
Common Btu (IT) inch/hour/sq. foot/°F to Btu (th) inch/second/sq. foot/°F Calculations
Quick-lookup reference table showing calculated equivalents for standard increments between Btu (IT) inch/hour/sq. foot/°F (Btu·in/(h·ft²·°F)) and Btu (th) inch/second/sq. foot/°F (Btu (th)·in/(s·ft²·°F)).
| Conversion & Equivalent Value | Scientific Notation |
|---|---|
| 0.001 Btu·in/(h·ft²·°F) 2.779637 × 10⁻⁷ Btu (th)·in/(s·ft²·°F) | 2.78 × 10⁻⁷ |
| 0.01 Btu·in/(h·ft²·°F) 2.779637 × 10⁻⁶ Btu (th)·in/(s·ft²·°F) | 2.78 × 10⁻⁶ |
| 0.1 Btu·in/(h·ft²·°F) 2.779637 × 10⁻⁵ Btu (th)·in/(s·ft²·°F) | 2.78 × 10⁻⁵ |
| 0.5 Btu·in/(h·ft²·°F) 0.000138982 Btu (th)·in/(s·ft²·°F) | 1.39 × 10⁻⁴ |
| 1 Btu·in/(h·ft²·°F) 0.000277964 Btu (th)·in/(s·ft²·°F) | 2.78 × 10⁻⁴ |
| 2 Btu·in/(h·ft²·°F) 0.000555927 Btu (th)·in/(s·ft²·°F) | 5.559 × 10⁻⁴ |
| 5 Btu·in/(h·ft²·°F) 0.00138982 Btu (th)·in/(s·ft²·°F) | 1.39 × 10⁻³ |
| 10 Btu·in/(h·ft²·°F) 0.00277964 Btu (th)·in/(s·ft²·°F) | 2.78 × 10⁻³ |
| 20 Btu·in/(h·ft²·°F) 0.00555927 Btu (th)·in/(s·ft²·°F) | 5.559 × 10⁻³ |
| 25 Btu·in/(h·ft²·°F) 0.00694909 Btu (th)·in/(s·ft²·°F) | 6.949 × 10⁻³ |
| 50 Btu·in/(h·ft²·°F) 0.0138982 Btu (th)·in/(s·ft²·°F) | 1.39 × 10⁻² |
| 100 Btu·in/(h·ft²·°F) 0.0277964 Btu (th)·in/(s·ft²·°F) | 2.78 × 10⁻² |
| 250 Btu·in/(h·ft²·°F) 0.0694909 Btu (th)·in/(s·ft²·°F) | 6.949 × 10⁻² |
| 500 Btu·in/(h·ft²·°F) 0.138982 Btu (th)·in/(s·ft²·°F) | 1.39 × 10⁻¹ |
| 1000 Btu·in/(h·ft²·°F) 0.277964 Btu (th)·in/(s·ft²·°F) | 2.78 × 10⁻¹ |
| Reciprocal & Equivalent Value | Scientific Notation |
|---|---|
| 1 Btu (th)·in/(s·ft²·°F) 3597.592433 Btu·in/(h·ft²·°F) | 3.598 × 10³ |
| 5 Btu (th)·in/(s·ft²·°F) 17987.962167 Btu·in/(h·ft²·°F) | 1.799 × 10⁴ |
| 10 Btu (th)·in/(s·ft²·°F) 35975.924334 Btu·in/(h·ft²·°F) | 3.598 × 10⁴ |
| 50 Btu (th)·in/(s·ft²·°F) 179879.621668 Btu·in/(h·ft²·°F) | 1.799 × 10⁵ |
| 100 Btu (th)·in/(s·ft²·°F) 359759.243336 Btu·in/(h·ft²·°F) | 3.598 × 10⁵ |
Real-World Context & Everyday Benchmarks
Tap to load into converterTo help contextualize these units in everyday life, science, and engineering, here are verified real-world reference points for Btu (IT) inch/hour/sq. foot/°F (Btu·in/(h·ft²·°F)) and Btu (th) inch/second/sq. foot/°F (Btu (th)·in/(s·ft²·°F)):
Btu (IT) inch/hour/sq. foot/°F References:
- Residential fiberglass batt thermal wall insulation (R-13) 0.28 Btu·in/(h·ft²·°F)
- Dry kiln-seasoned softwood framing lumber stud conductivity 0.85 Btu·in/(h·ft²·°F)
- Standard gypsum drywall interior plasterboard panel 1.1 Btu·in/(h·ft²·°F)
Btu (th) inch/second/sq. foot/°F References:
- Aero-engine cooling jacket cast iron thermal conductivity 0.01 Btu (th)·in/(s·ft²·°F)
How to Convert Btu (IT) inch/hour/sq. foot/°F to Btu (th) inch/second/sq. foot/°F
Converting Btu (IT) inch/hour/sq. foot/°F (Btu·in/(h·ft²·°F)) to Btu (th) inch/second/sq. foot/°F (Btu (th)·in/(s·ft²·°F)) is a core calculation in Thermal Conductivity, which measures a material's intrinsic capacity to conduct and transfer heat through microscopic collisions. This calculation navigates the boundary between the International Metric System (SI) and British Imperial / US Customary engineering standards. In contemporary metrology, Imperial units are defined in terms of exact SI standards via international agreements—notably NIST SP 811 and the 1959 International Yard and Pound Agreement. Exactly 1 Btu (IT) inch/hour/sq. foot/°F equals 0.000277964 Btu (th) inch/second/sq. foot/°F, while 1 Btu (th)·in/(s·ft²·°F) equals 3597.592433 Btu·in/(h·ft²·°F).
Mathematical Conversion Derivation via Coherent SI Base Unit
Under the International System of Quantities (ISQ), dimensional conversion between non-SI units is rigorously resolved by bridging through the coherent SI base unit (watt per meter kelvin (W/(m·K))) without arbitrary rounding:
1 Btu·in/(h·ft²·°F) = 0.144228 watt per meter kelvin (W/(m·K))1 Btu (th)·in/(s·ft²·°F) = 518.873162 watt per meter kelvin (W/(m·K))V(Btu (th)·in/(s·ft²·°F)) = V(Btu·in/(h·ft²·°F)) × ( 0.144228 / 518.873162 ) = V(Btu·in/(h·ft²·°F)) × 0.000277964Value in Btu (th) inch/second/sq. foot/°F = Value in Btu (IT) inch/hour/sq. foot/°F × 0.00027796367Direct computational formula applied for standard conversion.To convert 120 Btu (IT) inch/hour/sq. foot/°F (Btu·in/(h·ft²·°F)) to Btu (th) inch/second/sq. foot/°F (Btu (th)·in/(s·ft²·°F)): multiply 120 by 0.000277964 to get 0.0333556 Btu (th)·in/(s·ft²·°F). At an industrial engineering scale, 2500 Btu·in/(h·ft²·°F) converts to 0.694909 Btu (th)·in/(s·ft²·°F).
Inverse check: 1 Btu (th)·in/(s·ft²·°F) = 3597.592433 Btu·in/(h·ft²·°F).Understanding Btu (IT) inch/hour/sq. foot/°F and Btu (th) inch/second/sq. foot/°F
Btu (IT) inch/hour/sq. foot/°F
Btu·in/(h·ft²·°F)A Btu (IT) inch/hour/sq. foot/°F (Btu·in/(h·ft²·°F)) is an imperial and US customary unit for thermal conductivity.
Applications & Practical Context
In practical thermal conductivity terms, a residential fiberglass batt thermal wall insulation (R-13) equals 0.28 Btu·in/(h·ft²·°F), a dry kiln-seasoned softwood framing lumber stud conductivity equals 0.85 Btu·in/(h·ft²·°F), a standard gypsum drywall interior plasterboard panel equals 1.1 Btu·in/(h·ft²·°F).
A physical magnitude of 1 Btu·in/(h·ft²·°F) corresponds to 0.144228 W/(m·K) in standard SI measurement.
1 Btu·in/(h·ft²·°F) = 0.144228 W/(m·K)Btu (th) inch/second/sq. foot/°F
Btu (th)·in/(s·ft²·°F)A Btu (th) inch/second/sq. foot/°F (Btu (th)·in/(s·ft²·°F)) is an imperial and US customary unit for thermal conductivity.
Applications & Practical Context
In practical thermal conductivity terms, a aero-engine cooling jacket cast iron thermal conductivity equals 0.01 Btu (th)·in/(s·ft²·°F).
A physical magnitude of 1 Btu (th)·in/(s·ft²·°F) corresponds to 518.873162 W/(m·K) in standard SI measurement.
1 Btu (th)·in/(s·ft²·°F) = 518.873162 W/(m·K)Domain Metrology & Engineering Applications
Fourier's Law of Heat Conduction (q = -k · ∇T)
Rigorously quantified in laboratory and field settings using guarded hot plate apparatus (ASTM C177), laser flash thermal diffusivity analyzers, and transient plane source (TPS) sensors.
Applied across thermal interface material (TIM) development, architectural insulation manufacturing, aerospace heat shield design, and refractory ceramics under international metrology standard ISO 80000-5:2019, ASTM C177.
Formulas, conversion coefficients, and base definitions on this page strictly adhere to the ISO 80000-5:2019, ASTM C177 and the BIPM SI Brochure (9th Edition). Governed by Fourier's Law of Heat Conduction (q = -k · ∇T) under ISO 80000 dimensional vector [M L T⁻³ Θ⁻¹].
Thermal Conductivity to Heat Flux Density Bridge (W/m² • kW/m² • BTU/(h·ft²) • cal/(s·cm²))
Calculate Fourier conduction heat flux q" = k × ∇T across building envelopes and industrial heat exchangers, bridging thermal conductivity [M L T⁻³ Θ⁻¹] with heat flux density [M T⁻³].
q" = k × ∇T
[W/(m·K)] × [K/m] → [W/m²]
-
1. Normalize Input to SI Base Unit (W/(m·K)):
k = 1 Btu·in/(h·ft²·°F) × 0.14422789 = 0.14422789 W/(m·K) -
2. Apply Engineering Parameter (∇T):
Selected condition: Insulated Wall Core (20K across 0.1m = 200 K/m) at ∇T = 200 K/m -
3. Execute Governing Physical Law in SI Units:
q" = k × ∇T = (0.14422789 W/(m·K)) × (200 K/m) = 28.845578 W/m² -
4. Convert to Standard Engineering Units:
• W/m²: 28.845578 × 1 = 28.8456 W/m² (Watts per Square Meter) • kW/m²: 28.845578 × 0.001 = 0.02885 kW/m² (Kilowatts per Square Meter) • BTU/(h·ft²): 28.845578 × 0.317 = 9.144 BTU/(h·ft²) (BTU per Hour Sq. Foot) • cal/(s·cm²): 28.845578 × 2.3885 × 10⁻⁵ = 0.00068896 cal/(s·cm²) (Calories per Second Sq. Cm) • Ly/min: 28.845578 × 0.001433 = 0.04135 Ly/min (Langley per Minute) • MW/m²: 28.845578 × 1 × 10⁻⁶ = 2.884558 × 10⁻⁵ MW/m² (Megawatts per Square Meter)
| Engineering Substance / Operating Standard | Parameter Value (K/m) | Reference State / Condition | Typical Industrial & Engineering Application |
|---|---|---|---|
| Insulated Wall Core (20K across 0.1m = 200 K/m) | 200 |
200 K/m | Standard residential fiberglass/mineral wool batt |
| Solid Brick Masonry (25K across 0.25m = 100 K/m) | 100 |
100 K/m | Architectural structural brick veneer wall |
| Steam Boiler Tube Wall (100K across 0.005m = 20,000 K/m) | 20000 |
20,000 K/m | Carbon steel heat recovery steam boiler tube |
| CPU Copper Heat Spreader (30K across 0.002m = 15,000 K/m) | 15000 |
15,000 K/m | Semiconductor thermal interface heat spreader |
Frequently Asked Questions
Related Btu (IT) inch/hour/sq. foot/°F and Btu (th) inch/second/sq. foot/°F Conversions
Convert Btu (IT) inch/hour/sq. foot/°F to Other Units
Convert Other Units to Btu (th) inch/second/sq. foot/°F
Physically Coupled Thermodynamics & Heat Converters
Explore interconnected physical dimension converters within the Thermodynamics & Heat cluster (ISO 80000-5:2019).